Télécharger Imprimer la page

Hilti SJD 6 Mode D'emploi page 23

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 39
Stroke rate under no load
Stroke length
Maximum cutting performance in wood
Maximum cutting performance in aluminum
Maximum cutting performance in unalloyed steel
Cutting angle (left/right)
Suction adapter outside diameter
4.2
Noise information and vibration values in accordance with EN 62841
The sound pressure and vibration values given in these instructions were measured in accordance with a
standardized test and can be used to compare one power tool with another. They can also be used for a
preliminary assessment of exposure.
The data given represent the main applications of the power tool. However, if the power tool is used for
different applications, with different accessory tools, or is poorly maintained, the data can vary. This can
significantly increase exposure over the total working period.
An accurate estimation of exposure should also take into account the times when the tool is switched off, or
when it is running but not actually being used for a job. This can significantly reduce exposure over the total
working period.
Identify additional safety measures to protect the operator from the effects of noise and/or vibration, for
example: maintaining the power tool and accessory tools, keeping the hands warm, organization of work
patterns.
Noise emission values
Sound power level (L
WA
Uncertainty for the sound power level (K
Sound pressure level (L
Uncertainty for the sound pressure level (K
Total vibration
Vibration emission value for sawing wood sheets (a
Vibration emission value for sawing sheet metal (a
Uncertainty (K)
5
Using extension cords
WARNING
A damaged supply cord presents a hazard! Do not touch the supply cord or extension cord if damaged
while working. Disconnect the supply cord plug from the power outlet.
▶ Check the appliance's supply cord at regular intervals and have it replaced by a qualified specialist if
found to be damaged.
Use only extension cords of a type approved for the application and with conductors of adequate gauge
(cross section). The power tool may otherwise suffer a drop in performance and the extension cord may
overheat.
Check the extension cord for damage at regular intervals.
Replace damaged extension cords.
When working outdoors, use only extension cords that are approved and correspondingly marked for
this application.
Information on recommended minimum conductor cross-sections and cable lengths is accessible via
a link, in the form of a QR code, at the end of this document.
*2143763*
)
)
WA
)
pA
)
pA
2143763
)
h,B
)
h,M
SJD 6
80 /min ... 3,000 /min
28 mm
150 mm
25 mm
10 mm
0°, 15°, 30°, 45°
27.5 mm
SJD 6
100.5 dB(A)
5 dB(A)
89.5 dB(A)
5 dB(A)
SJD 6
9.7 m/s²
8.0 m/s²
1.5 m/s²
English
17

Publicité

loading