Attention: The fitting must be installed, flushed and
tested after the valid norms.
The mixer can not used together with a continuous
flow water heater.
Assembly
1. Flush through the supply pipes.
2. Place the mixer including the sealing washer in
position on the basin.
3. Slip the fixation piece including the washer
over the threaded pin and tighten the nut.
4. Connect the supply pipes to the angle valves;
cold right - hot left.
5. Connect the Isiflex hose with the handshower
and the mixer.
Large differences in pressure between the hot and
cold water supply should be balanced.
Operation
The mixer is actuated by lifting the lever head.
Swivel to the left = hot water,
swivel to the right = cold water.
The handshower is activated by pressing the button,
the spout of the mixer is closed. After the button is
released, the handshower is closed und the spout
of the mixer is activated.
Technical Data
Operating pressure:
Recommended operating pressure: 0.25 - 0.5 MPa
Test pressure:
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Rate of flow mixer:
Rate of flow handshower:
To adjust the hot water limiter on single lever mixers,
please see page 16.

All manuals and user guides at all-guides.com
max. 1 MPa
1.6 MPa
max. 80° C
65° C
6.5 l/min 0.3 MPa
8.5 l/min 0.3 MPa
English
Spare parts (see page 3)
1
handle
1.1 screw cover
2
flange
3
nut
4
cartridge cpl.
5
locking screw
6
aerator cpl.
7
fixing set
8
Isiflex hose 1,6 m
9
handshower
10
chain for plug
32097000
96338000
96656000
96690000
92730000
96059000
13913000
96016000
28276000
32128000
97109000

Publicité

Table des Matières
loading

Table des Matières