Télécharger Imprimer la page

OHAUS MB35 Guide D'utilisateur page 10

Masquer les pouces Voir aussi pour MB35:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

EN-6
2.5 Operating Controls
The MB35 Moisture Analyzer controls are grouped as operating buttons and function buttons with three modes of
operation.
EDIT MODE - The user is changing a parameter, no test running.
RUN MODE - The unit is in process of running a test.
RESULT MODE - Final result.
OPERATING BUTTONS
On/Off
Turns display on and off.
Starts the drying process (Run Mode). Ends drying process (Enters Stop Mode).
START
STOP
Tares the balance. (Enters Run Mode). Accepts selection in Edit Mode. Ends Result Mode.
TARE
FUNCTION BUTTONS
EDIT MODE
ONLY
EDIT MODE
ONLY
EDIT MODE
100
°
10:00
CLEAR
0.000 g
0.000 g
0.000 g
0.000 g
0.000 g
PAN
PRESS
* * * * *
TARE
100 °
10:00
CLEAR
0.000 g
0.000 g
0.000 g
0.000 g
0.000 g
PAN
PRESS
* * * * *
TARE
ANALYZER SETUP
ANALYZER SETUP
ANALYZER SETUP
ANALYZER SETUP
ANALYZER SETUP
WEIGHT CAL
TEMP CAL
TIME-DATE
RS232
PRINT
EXIT
MB35
HALOGEN
On / Off
Print
Menu
START
STOP
MB35 Panel Controls
Initial press of
button highlights tempera-
ture numerals. Additional presses increases
temperature setting in 5 degree increments.
Initial press of
button highlights shut-off
selection. Additional presses steps through
options, AUTO or TIMED (Minutes/seconds).
In a non-run mode, initial press of
brings up the ANALYZER SETUP screen.
MB35
TARE
button

Publicité

loading