Télécharger Imprimer la page

Daspi E-SOFT Manuel D'utilisation page 5

Publicité

Les langues disponibles

Les langues disponibles

programming time automatic closing (pause time):
1) With the gate closed, press and release seT button. The DL10 LED starts flashing.
2) Press breaK button . The control panel starts timing and it activates the flasher
3) Press breaK button again.Timing will stop and resulting time will be stored as pausing time before automatic closing.
desabling automatic reclosing:
1) With the gate closed, press and release seT. The DL10 LED starts flashing
2) Press t BREAK button twice until the DL10 LED turns off.
sToriNg aNd deleTiNg radio codes
press and release seT button (led dl10 flashes).
Push desired button on remote control to be stored. The control board will automatically store radio code and terminate the procedure.(LED DL10 turns off).
a maximum of 32 different codes can be stored.
storing radio code for pedestrian ped command. press the seT button twice (led dl10 flashes fast). Push desired button on remote control for pedestrian opening to be stored. The control
board will automatically store radio code and terminate the procedure.(LED DL10 turns off). a maximum of 32 different codes can be stored.
cancellation of all radio codes.
press at the same time seT and breaK buttons for 10 seconds until led dl10 flashes quickly. Release the buttons, led DL10 turns off and all the codes will be erase.
TermiNals descripTioN
N.B. If inputs which are normally closed (N.C.) are not being used, they must be bridged. If more than one N.C. contacts are used on the same terminal inputs, they must be connected in series.
If more than one N.O. (normally open) contacts are used on the same input they must be connected in parallel.
Pedestrian input: opens only motor M1. N.O. contact
1
2
START input: it stops the gate during opening while during closing it reverses.
1
3
N.O. Contact
STOP input: it stops any operation in progress and override automatic closing.
1
N.C. Contact
4
Input for photocells They areactive only while gate is closing: they will stop
7
and reverse the gate. N.C. contact
5
Photocells input. They are active both during opening (stops and opens again
7
the gate) and during closing (stops and reverses the gate) N.C. Contact
6
Input mechanical safety edge command. Enabled both on opening and on
8
closing, the gate stops and reverses 10 cm. N.C. Contact
10
Input open command. N.O. Contact. For connecting a timer. Opening command.
9
As long as it remains closed, it does not accept any other commands.
10
Output for 230 Vac 50/60 Hz flashing device max 100 Watt overall
11
12
Check proper working of all safety devices installed in order to reduce the risk of injury to the minimum. Give information to t people involved in the use of the gate about operations and commands,
safety devices and any danger arising from the use of the automation. Fill in the technical installation file and comply with current regulations.
1 2 3 4 5 6
1 2 3
RX 433Mhz
F1 1.6A
SW1
ON
1 2 3 4
23 24 25
12Vac
E-Lock
24Vac
SET
BREAK WORK
DL1 DL2 DL3 DL4 DL5 DL6 DL7
1
2
3
4
5
6
7
8
Output courtesy light power supply 90 seconds. Max.100W 230 Vac 50/60 Hz
12
13
MOTOR M1 output (also for pedestrian), maximum 500 Watt. Terminals: 14
14
15
common, 16 closing, 15 opening. Capacitor between terminals 15-16
16
17
MOTOR M2 output, maximum 500 Watt. Terminals: 17 common, 19 closing, 18
18
opening. Capacitor between terminals 18-19
19
Power supply input from mains 230 Vac 50/60 Hz
21
22
12 Vac output for electrical lock, maximum load 15 Watt
23
24
24 Vac output for power supply to external devices such as photocells (max
24
500mA)
25
Antenna 26 input (antenna screen) 27 (hot pole)
26
27
Contact for the gate position or courtesy light. Dry contact max. 50 mA
28
29
DL10
26 27 28 29
SW2
1 2 3 4
DL9
DL8
MIN
MAX
POWER
9 10
11 12 13 14 15 16 17 18 19
20
M2
M1
F2 5A
21
22
G
F
N
230Vac
50/60 Hz

Publicité

loading

Produits Connexes pour Daspi E-SOFT