4-3. Unit Overload

If unit is used beyond capacity (excessive wire feed, shorted output, etc.), wire feeds but is not energized. Release gun
trigger to reset this condition.

4-4. Changing Drive Roll And Wire Inlet Guide

Tools Needed:
5/64 in
7/16 in

4-5. Aligning Drive Rolls And Wire Guide

Tools Needed:

4-6. Replacing Gun Contact Tip

Tools Needed:
All manuals and user guides at all-guides.com
3
2
1
4
Correct
4
3
2
1
5
Incorrect
5
2
1
1
Securing Screw
2
Inlet Wire Guide
Loosen screw. Slide tip as close to
drive rolls as possible without touch-
ing. Tighten screw.
3
Anti-Wear Guide
Install guide as shown.
4
Drive Roll
Install correct drive roll for wire size
and type.
5
Drive Roll Securing Nut
Turn nut one click to secure drive
roll.
ST-150 227-C
Y Turn Off power.
View is from top of drive rolls look-
ing down with pressure assembly
open.
1
Drive Roll Securing Nut
2
Drive Roll
3
Wire Guide
4
Welding Wire
5
Drive Gear
Insert screwdriver, and turn screw
in or out until drive roll groove lines
up with wire guide.
Close pressure roll assembly.
Close door.
Ref. ST-800 412-A
Y Turn
Off
power
before
replacing contact tip.
1
Nozzle
2
Contact Tip
Cut off welding wire at contact tip.
Remove nozzle.
Remove contact tip and install new
contact tip. Reinstall nozzle.
Ref. 800 797-C
OM-194 430 Page 21