Section 4 - Maintenance And Troubleshooting; Routine Maintenance; Circuit Breaker Cb1 - Hobart Welding Products BETA-MIG 2510 Manuel Du Propriétaire

Table des Matières

Publicité

SECTION 4 – MAINTENANCE AND TROUBLESHOOTING

4-1. Routine Maintenance

3 Months
Replace unreadable labels.
6 Months
Blow out or vacuum
inside. During heavy
service, clean monthly.

4-2. Circuit Breaker CB1

1
OM-194 430 Page 20
All manuals and user guides at all-guides.com
Y Disconnect power before maintaining.
Clean and tighten weld terminals.
OR
3
Repair or replace
cracked weld cable.
Remove drive roll and
carrier. Apply light coat
of oil or grease to drive
motor shaft.
2
1
Circuit Breaker CB1
If CB1 opens, wire feeding stops.
2
Welding Gun
Check gun liner for blockage or
kinks.
3
Wire Drive Assembly
Check for jammed wire, binding
drive gear or misaligned drive rolls.
Allow cooling period and reset
breaker. Close door.
Ref. ST-801 789 / Ref. 800 797-C

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

M-25 gun

Table des Matières