8000
The instruction manual is downloadable from the site www.
vimar.com
Description
The 8000 series consists of a group of primary modular
elements which enable the composition of entrance panels
for interphones and video door entry systems which utilise
various technologies and for various types of installation:
flush-mounted with rainproof cover or surface-wall mounted
with rainproof cover.
The components are made of extruded aluminium with
a special weatherproof paint finish and copolymers with
outstanding technical properties.
The 8000 series is compatible with analogue and digital
Elvox systems, Sound System, AC call, Due Fili and Digibus
systems, for versions with individual buttons or with a keypad
and display.
These instructions refer only to entrance panel mounting;
for complete installation, wiring and programming directions
please consult the manual for the electronic unit.
The assembly and installation process for 8000 series
entrance panels with electronic units for Due Fili or
Digibus systems must include the following steps:
1 - Select the modules making up the entrance panel (see
"Standard modules" and "Additional modules" below).
2 - Select the module holder frames (art. 8092, 8082, 8093,
8083) in accordance with the modules to be added. Use
frames art. 8092 and 8093 to combine the standard
module with the additional modules and frames art.
8082 and 8083 for additional modules only.
3 - Select the boxes and frames for flush-mounted or
surface wall-mounted installations.
4 - Install the entrance panel as described below.
Installation
Flush-mounted entrance panel installation with rainproof
covers
Installation of the flush-mounted entrance panels requires
use of the back boxes art. 9192 or 9193 respectively for 2 or
3 electronic modules mounted vertically (fig. 2).
If the panel uses more than one back box, the rainproof
covers must also be used (see accessories: series 92xx
rainproof covers, fig. 3), in accordance with the number of
modules fitted vertically and horizontally.
Important: During installation of flush-mounted back box art.
9192 or 9193, leave the cover cap (supplied) on in order to
prevent any deformation of the box itself.
Surface-wall mounted entrance panel installation
Installation of the surface wall-mounted panels requires
use of the boxes series 93xx, available in 2- to 12-module
versions (fig. 4). Use of the surface wall-mounted boxes
requires combination with the 92xx series rainproof covers
(fig. 3), in the same dimensions as the boxes used.
4

Installation procedure:

- Install the flush-mounted or surface wall-mounted box with
the bottom edge at a height of approx. 1.65 m from the
ground (fig. 5). Use the relevant hole in the box to route
the wires.
If the flush-mounted installation requires a combination of
several boxes, use the hooks supplied with the boxes to
secure them together (fig. 6).
- Fix the electronic unit terminal block underneath the
module support frame using the screws supplied (fig. 7).
- Fix the rainproof cover and the module support frame to
the box using the screws supplied with the frames (fig. 9A,
9B).
- Connect the electronic unit terminal block to the system,
observing the wiring diagrams in the relevant manual in
accordance with the system type.
- Connect the electronic unit to the terminal block by means
of the wiring on the upper section of the unit (fig. 10A,
10B).
- If using an entrance panel with conventional buttons,
connect any additional modules (fig. 11); they should be
connected one after the other by means of the wiring
supplied with the modules, and finally connected to the
standard electronic unit by means of the wiring in its lower
section.
Note: The connection of more than one additional module
may necessitate the use of an additional power supply unit
art. 6582 to power the LED lighting.
- Fit the electronic unit and any additional modules in the
frames. Use the partition supplied with the additional
modules to keep them joined together (fig. 12).
- Fit the microphone in the lower right-hand section of the
frame (fig. 13).
- Configure and program the entrance panel parameters
(externally using a programmer or specific software).
- Fit the cover plates for the modules in the frames (fig. 14A,
14B).
- Close the entrance panel, attaching the cover plate first
in the upper section and then securing the lower section
by means of a screwdriver on the head section (fig. 15A,
15B).
- To remove the name card for modules with conventional
buttons, use your fingers to press gently and remove the
card retainer on the rear of the button module (fig. 16).
- If additional modules with illuminated name card (art.
805N) or street number (art. 80PN) are installed, the
LED lighting circuit (supplied with the modules) should be
installed in the module support frames and powered by
means of connection to the electronic unit terminal block
(as indicated in the wiring variant descriptions). The card
or street number can be removed from the back of the
module as shown in fig. 17.

Publicité