Attention: If you wish to use the magnetic
detector only with the internal magnet, on
the azone Z4 you MUST put a jumper in Ter-
minal 1.
For detectors WL04MM2 and WL04MB2 you can make a similar acquisition. The channel for the magnetic contact can be
acquired in any area. The channel for the external detector RF45 can be acquired only on the zones Z1, Z2 and Z3.
ATTENTIOM: If you are acquiring different types of sensors in the same area, the fire alarm generated by WL04RF detector
will be seen as a general alarm. Therefore, it's suggested the aquisition of smoke detectors WL04RF in one area
Procedure of acquisition:
1. The interface is in NORMAL operating mode with the green led (Fig.1: 1) on;
2. Start the acquisition mode by pressing for 3 seconds the LEARN button (Fig. 1: 7), the LED (Fig.1:1) will light red while the
LED Z1 (Fig.1: 2) will light orange;
3. Pressing the LEARN button move to the zone (Z1, Z2, Z3, Z4, Snd) in which you want to recognize the device. The zone
indicator will light orange; ATTENTION: The wireless siren and telephone dialler should be acquired in the zone "Snd";
4.Follow the procedure of acquiring of wireless devices;
5.The interface confirms the acquisition through a series of 5 BEEP;
6.Press once the RESET button to enable or disable the tamper event of the selected zone:
7.
Continue with the recording of devices in the same zone or move to the next one by pressing the LEARN button
8.
To exit the acquisition, press the LEARN button to enter the NORMAL mode (all LEDs are lit green).
Functioning mode:
By LEARN button it's possible to accede to different functioning mode:
MODE
NORMAL
The Leds indicate the status of the zones
TROUBLE
The Leds indicate possible problems of the system (divided in zones)
LEARN
Acquisition of the devices in the system and abilitation/ disabilitation of TAMPER signal of the devices
Function of programming buttons:
LEARN and RESET buttons are used to program MOD-WL04 and have different function, depending on the use:
Button
Mode
LEARN
NORMAL
TROUBLE
LEARN
Collegare i cavi
in un contatto
NC
Connect the cables
by a Normally Closed
connection
Connecter les câbles
par une connexion
Normalement Fermée
Led Color zone Z
Green
Orange
Operation
Press once
Pass to TROUBLE mode to show system troubles
3 seconds press
Pass to LEARN mode for devices acquisition;
Press once
Pass in NORMAL mode;
Pass to the next zone Z1, Z2, Z3, Z4, Snd activating a BEEP.
Press once
When the cycle is ended one pression restore the normal
mode of the system;
Example of acquisition:
zone Z1 Infrared detector WL04IR
zone Z2 Remote control WL04TC
zone Z3 Magnetic Contact WL04MB + RF45
zone Z4 Magnetic Contact WL04MB + wired magnetic device
Function
Tamper protection disabled
Tamper protection enabled
Function
Function