Scotsman  products  are  designed  and 
manufactured according to the highest 
safety  and  quality  standards;  this 
particular 
equipment 
designed  to  be  installed  within  the 
following operating limits:  
 
 
Ambient temperature   10°C 
Water temperature 
Water hardness 
Water pressure 
Voltage 
 
Any  use  of  the  machine  outside  these 
limits  or  outdoor  will  automatically 
forfeit your warranty.  
Should the mains water you use fail to 
meet the above‐mentioned parameters 
we  recommend  that  you  use  an 
external water treatment device. 
Scotsman  reserves  the  right  to  make 
changes  at  any  time,  without  warning 
and with no obligation.  
The  sound  level  generated  by  the 
equipment when in operation is lower 
than 70 dB(A). 
 
Location  
It  is  important  that  the  machine 
installation location ensures that there 
is  enough  clearance  on  the  outside  to 
allow  access  during  maintenance 
operations  and  that  there  is  a  free 
space of at least 15 cm on all sides for 
 
has 
been 
Min 
Max 
38°C 
10°C 
35°C 
10 °fH 
20°fH 
0.1 Mpa 0.6 Mpa 
‐10% 
+10% 
proper  ventilation;  where  possible, 
avoid  hot  and  dusty  locations.  Make 
sure  that  the  equipment  is  properly 
levelled with the counter onto which it 
rests. 
This machine is NOT suitable for 
outdoor use and NOT suitable for 
installation in an area where a water 
jet could be used for cleaning. 
 
WARNING: the air blow‐out grills 
located on the rear and left side 
panel must always be unobstructed. 
Never place any objects that may 
obstruct them.  
Do not locate multiple portable 
socket‐outlets or portable power 
supplies at the rear of the appliance.
 
Water supply connections   
At time of installation replace the 
old/used water hoses with the new 
ones supplied in the machine. 
All  water  supply  connections  must  be 
carried  out  according  to  the  highest 
standards and in compliance with local 
regulations.  
 
Water supply 
Use  drinkable,  clean  and  cold  water. 
Water flows into the machine through 
the rubber hose connected to the 3/4" 
male fitting located on the rear side of 
the equipment.  A water shut‐off valve 
(tap)  should  be  installed  near  the 
machine installation location. 
 