Table Des Matières; Introduction; Warranty; Installation - Scotsman Ice CME506 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

User Manual for
Modular Ice Cubers
models
CME506 - CME656 -
CME806
TABLE OF CONTENTS
Introduction . . . . . . . . . . . . . . . . . PAGE 2
Warranty . . . . . . . . . . . . . . . . . . PAGE 2
Installation . . . . . . . . . . . . . . . . . PAGE 2
Plumbing . . . . . . . . . . . . . . . . . . PAGE 3
Electrical . . . . . . . . . . . . . . . . . . PAGE 3
Final Check List. . . . . . . . . . . . . . . PAGE 3
Initial Start Up . . . . . . . . . . . . . . . PAGE 4
Maintenance. . . . . . . . . . . . . . . . . PAGE 5
Failure Analysis. . . . . . . . . . . . . . . PAGE 5

INTRODUCTION:

This product manual contains the information needed for the
setup, installation, initial start up, sanitation and
maintenance of this ice machine. Keep it for future
reference.
There are 3 models covered in this manual: CME506 or
CME656 or CME806.

WARRANTY:

The warranty conditions are those supplied by the official
distributor for your area. In case of parts, only GENUINE
service parts may be used.
TO INSTALL THE MACHINE
This machine is designed to fit the following Scotsman
storage bins:
B 390 or BH 550 or any other 762mm wide Scotsman Ice
Storage Bins.
In addition, there may be other bins that can be used, check
Scotsman's sales literature for application information.
A stacking kit, for like models, is KSCME656.
Note: This model fills the bin very full, and only shut off
when ice has filled the bin enough to back up into the base
of the ice machine.
Installation Limitations:
This ice system is designed to be installed indoors, in a
controlled environment:
Min
Air Temperature
Water Temperature
Water Pressure
Voltage
(Compared to the nameplate)
Operating the machine outside of the limitations is misuse
and can void any warranty.
Scotsman Ice Systems are designed and manufactured with
the highest regard for safety and performance.
Scotsman reserves the right to make design changes and/or
improvements at any time.
Specifications and design are subject to change without
notice.
LOCATION & ASSEMBLY:
After uncrating and inspection, the unit is ready for
installation. It is important that the machine be installed in a
location where it has enough space around it to be accessible
for service, and minimum of 150 mm be allowed at the back,
left and right sides for air circulation on air cooled models.
If installed in a corner or with another cabinet next to the
right/left side, a air baffle should be installed on the back of
the cabinet to minimize air re-circulation.
Try to avoid hot, dirty and crowded locations.
2
Max
10 C
40 C
5 C
40 C
1 bar
5 bar
-5%
+10%

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cme656Cme806

Table des Matières