NOTICE
Contaminated surface!
The system and surroundings can be contaminated by germs.
Do not store or consume any food in the same room.
Avoid touching the surface, remove visible dirt.
After work is complete, wash your hands.
Prescribed personal protective equipment!
Always use personal protective equipment during installation, maintenance and disposal work on the system.
CAUTION
Pumps can start up unexpectedly.
Before undertaking maintenance or repair work on the system, switch it off or disconnect it from the power supply.
The pump must never run dry or in slurping operation; the multi-vane impeller and pump housing must always be
flooded up to at least the minimum immersion depth.
The pump must never be used when there are people in the water or the pressure pipe is not connected.
The pump builds up a pumping pressure/excess pressure.
2.3
Intended use
The system must be used only for the pumping of normal household faecal wastewater, but not for combustible or explosive
liquids or solvents.
WARNING
Use of the system in a potentially explosive environment (ATEX) is not permitted.
All modifications or attachments that are carried out without the express and written permission of the manufacturer, the use
of non-genuine spare parts and repairs carried out by companies or persons not approved by the manufacturer will lead to a
loss of warranty.
The control unit is equipped with a protective circuit to protect the system's electrical components from damage in case of
possible voltage peaks.
This does not protect against lightning.
If such requirements exist, an appropriate protective device must be installed on site.
2.4
Product description
The Aqualift F lifting station (referred to as the "system" in the following) is designed for pumping off faecal and faecal-free
wastewater. The system tank houses the pump(s) and the level sensor(s). The assemblies are matched to the KESSEL con-
trol unit supplied.
The system is available in two different versions (capacities) and with different pumps. With polymer shut-off valve, depend-
ing on requirements.
Versions
Type designation
Aqualift F Mono
Aqualift F Duo
010-907
Protective clothing
Protective gloves
Safety footwear
Face protection
Tank volume
50 litres
120 litres
Lifting station/Installation and operating instructions
Pump/control unit connection values
230V
X
X
400V
X
X
21 / 100