Checks to electrical devices - Repair and maintenance to electrical components shall include
initial safety checks and component inspection procedures. If a fault exists that could
compromise safety, then no electrical supply shall be connected to the circuit until it is
satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to
continue operation, an adequate temporary solution shall be used. This shall be reported to
the owner of the equipment so all parties are advised.
Initial safety checks shall include:
-those capacitors are discharged: this shall be done in a safe manner to avoid possibility of
sparking;
-that there no live electrical components and wiring are exposed while charging, recovering
or purging the system;
-that there is continuity of earth bonding.
Install the unit in rooms which exceed 10 m². Do not install the
unit in a place where inflammable gas may leak.
WARNING!
The manufacture may provide other suitable example or may
provide additional information about the refrigerant odour.
NOTE!

3. PRODUCT OVERVIEW

1 - Control panel
2 - Air outlet with adjustable louver
3 - Handle
4 - Air inlet with air filter
5 - Caster
6 - Drainage Hole
7 - Air Exhaust
Note: The appearance is only for reference. Please see the real product for detailed
information.