• The unit is designed only for use with R-290(propane) gas as the designated
refrigerant.
• The refrigerant loop is sealed. Only a qualified technician should attempt to service!
• Do not discharge the refrigerant into the atmosphere.
• R-290 (propane) is flammable and heavier than air.
• It collects first in low areas but can be circulated by the fans.
• If propane gas is present or even suspected, do not allow untrained personnel to
attempt to find the cause.
• The propane gas used in the unit has no odor.
• The lack of smell does not indicate a lack of escaped gas.
• If a leak is detected, immediately evacuate all persons from the store, ventilate the
room and contact the local fire department to advise them that a propane leak has
occurred.
• Do not let any persons back into the room until the qualified service technician has
arrived and that technician advises that it is safe to return to the room.
• No open flames, cigarettes or other possible sources of ignition should be used
inside or in the vicinity of the units.
• Component parts are designed for propane and non-incentive and non-sparking. •
Component parts shall only be replaced with identical repair parts.
FAILURE TO ABIDE BY THIS WARNING COULD RESULT IN AN EXPLOSION, DEATH,
INJURY AND PROPERTY DAMAGE.

2. FOR YOUR SAFETY

Your safety is the most important thing we concerned!
Please read this manual carefully and fully understand before
operating your appliance.
WARNING

OPERATIONAL PRECAUTIONS

WARNING- to reduce the risk of fire, electric shock or injury to persons or property:• If
the supply cord is damaged, it must be replaced by the manufacturer, its service agent
or similarly qualified persons in order to avoid a hazard.
• The appliance shall be disconnected from its power source during service.
• Always operate the unit from a power source of equal voltage, frequency and rating as
indicated on the product identification plate.
• Always use a power outlet that is grounded.
• Unplug the power cord when cleaning or when not in use.
• Do not operate with wet hands. Prevent water from spilling onto the unit.
• Do not immerse or expose the unit to rain, moisture or any other liquid.
• Do not leave the unit running unattended. Do not tilt or turn over the unit.
• Do not unplug while the unit is operating.