sYmptOm
Light will not come on.
Light comes on in day-
light.
Light comes on for no
apparent reason.
Light stays on continu-
ously.
Light flashes on and off.
please call 1-800-858-8501 (english speaking only) for assistance before returning
If you experience a problem, follow this guide. You may also want to visit our Web site at: www.hzsupport.
com. If the problem persists, call* for assistance at 1-800-858-8501 (English speaking only), 7:30 AM to
4:30 PM CST (M-F). You may also write* to:
HeathCo LLC
P.O. Box 90045, Bowling Green, KY 42102-9045
ATTN: Technical Service
* If contacting Technical Service, please have the following information available: Model Number, Date
of Purchase, and Place of Purchase.
598-1316-02

trOubLesHOOting guiDe

pOssibLe cause
1. Plastic battery tab has not been removed
from battery compartment.
2. Batteries are dead.
3. Sensor is turned OFF.
4. Daylight turn-off is in effect.
1. Light may be installed in a relatively
dark location.
2. Light control is in TEST.
1. Light control may be sensing small
animals or automobile traffic.
2. Range is set too high.
1. Light control is detecting a heat source
like an air vent, dryer vent, or brightly-
colored heat-reflective surface.
2. Light control is in TEST.
1. Heat being reflected from other objects
may be affecting the sensor.
2. Light control is in the T EST mode and
warming up.
3. Batteries are almost dead.

tecHnicaL serVice

product to store.
no service parts available for this product
sOLutiOn
1. Remove plastic tab from battery compart-
ment.
2. Switch the sensor OFF and let the battery
charge for two or more sunny days before
using again.
3. Turn sensor ON.
4. Recheck after dark.
1. Relocate light to an area that receives more
light.
2. Set control switch to 1 or 5 minute posi-
tion.
1. Reduce RANGE.
2. Reduce RANGE.
1. Relocate light or reduce RANGE.
2. Set control switch to 1 or 5 minute posi-
tion.
1. Reduce RANGE.
2. Flashing is normal under these condi-
tions.
3. Reduce RANGE. If flashing continues,
switch the sensor OFF and let the battery
charge for two or more sunny days before
using again.