Télécharger Imprimer la page

Bosch DLE 70 Professional Notice Originale page 27

Masquer les pouces Voir aussi pour DLE 70 Professional:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 31
26 | English
Working with the Tripod (Accessory)
The use of a tripod is particularly necessary for
larger distances. Position the measuring tool
with the 1/4" thread 17 onto the quick-change
plate of the tripod 23 or a commercially available
camera tripod. Tighten the measuring tool with
the locking screw of the quick-change plate.
Set the corresponding reference level for meas-
urement with a tripod by pushing button 1 (the
reference level is the thread).
Troubleshooting
Corrective Measures
Cause
Temperature warning indicator (c) flashing;
measurement not possible
The measuring tool is not
within the operating tem-
perature range of –10 °C
to +50°C; for continuous
measurements (functions
minimum/maximum
measurement) to +40 °C.
Battery low indicator (b) appears
Battery voltage decreas-
ing (measurement still
possible)
Battery low indicator (b) flashing; measure-
ment not possible
Battery voltage too low
2 609 140 692 | (14.12.09)
Causes and
Corrective
Measure
Wait until the
measuring tool
has reached the
operating temper-
ature
Replace batteries/
rechargeable bat-
teries
Replace batteries/
rechargeable bat-
teries
Cause
"Error" and "––––" indication in display
The angle between the la-
ser beam and the target is
too acute.
The target surface reflects
too intensely (e.g. a mir-
ror) or insufficiently (e.g.
black fabric), or the ambi-
ent light is too bright.
The laser beam outlet 21
or the reception lens 22
are misted up (e.g. due to
a rapid temperature
change).
Calculated value is great-
2
er than 99999 m/m
"Error" indication flashes at in display (top)
Addition/Subtraction of
measured values with dif-
ferent units of measure
Measuring result not plausible
The target surface does
not reflect correctly (e.g.
water, glass).
The laser beam outlet 21
or the reception lens 22
are covered.
Wrong reference level set Select reference
Obstruction in path of la-
ser beam
Corrective
Measure
Enlargen the angle
between the laser
beam and the tar-
get
Work with the la-
ser target plate 25
(accessory)
Wipe the laser
beam outlet 21
and/or the recep-
tion lens 22 dry
using a soft cloth
Divide calculation
3
/m
.
into intermediate
steps
Only add/subtract
measured values
with the same
units of measure
Cover off the tar-
get surface
Make sure that the
laser beam outlet
21 or the recep-
tion lens 22 are
unobstructed
level that corre-
sponds to meas-
urement
Laser point must
be completely on
target surface.
Bosch Power Tools

Publicité

loading