Installation instructions
Installing a 3-wire conduit
Aluminum building wire may be used but it must be rated for the correct
amperage and voltage to make the connection. Connect wires according to
Step 4 depending on the number of wires.
Wire used, location and enclosure of splices, etc., must conform to good wiring
practices and local codes.
Ground
Neutral
strap
terminal
White
Black
Red
Black
White
Red
Wire tips
20 English
Install_NY63T8751S_DG68-01305A-01_EN+CFR.indb 20
1.
Loosen the 3 lower terminal screws
from the terminal block.
2.
Insert the center bare wire (white/
neutral) tip through the bottom center
terminal block opening. On certain
models, the wire will need to be
inserted through the ground strap
opening and then into the bottom
center block opening.
3.
Insert the two side bare wire tips into
the lower left and the lower right
terminal block openings.
4.
Tighten the screws until the wire is
firmly secured (35 to 50 inch-lbs.). Do
not over-tighten the screws since it
could damage the wires.
Go to step 6 on page 21 and proceed
5.
with the installation.
Installing a 4-wire conduit
Aluminum building wire may be used but it must be rated for the correct
amperage and voltage to make the connection. Connect wires according to this
Step 4 depending on the number of wires.
Wire used, location and enclosure of splices, etc., must conform to good wiring
practices and local codes.
Ground strap
Ground plate
Red
Black
White
Neutral
terminal
Wire
White
Red
tips
Black
Ground wire
(Green)
1.
Loosen the 3 lower terminal screws
from the terminal block. Remove the
ground screw and ground plate and
retain them.
2.
Cut and discard the ground strap. Do
not discard any screws.
Insert the ground bare wire tip between
3.
the range frame and the ground plate
(removed earlier) and secure it in
place with the ground screw (removed
earlier).
Insert the bare wire (white/neutral)
4.
tip through the bottom center of the
terminal block opening.
5.
Insert the two side bare wire tips into
the lower left and the lower right
terminal block openings.
6.
Tighten the screws until the wire is
firmly secured (35 to 50 inch-lbs.). Do
not over-tighten the screws since it
could damage the wires.
7.
Go to step 6 and proceed with the
installation.