Output module CPX-2AA-U-I
General technical specifications of
the CPX terminal
Protection class as per EN 60529
Operating voltage supply
– Rated voltage
– Internal current consumption at
24 V (internal electronics, no
current consumption at outputs)
– Maximum current consumption
at 24 V (maximum current con-
sumption at outputs)
Load voltage supply
– Rated voltage
– Maximum current consumption
at 24 V
– Diagnostic message undervol-
tage V
(monitoring V
OUT
OUT
voltage outside function range)
Analogue outputs
– Channels
– Output ranges
(single-ended outputs)
Festo CPX-AX 0206NH English
Voltage
Current
outputs
outputs
See CPX system manual
See technical specifications of
the fitted sub-base
V
(electronics/sensors)
EL/SEN
24 V DC ± 25 %
Typ. 50 mA
Typ. 100 mA
V
(outputs)
OUT
24 V DC ± 25 %
4...10 A (response current
of fuse)
17...14 V
, load
Total of 2 output channels per
module
Max.
Max.
2 channels
2 channels
0...10 V
0...20 mA /
4...20 mA