Installing The Vulcan Motor Reducer Gear Unit; Electrical Connections - AS Torantriebe R50 24V Notice D'emploi Et D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

INSTALLING THE VULCAN MOTOR REDUCER
GEAR UNIT
1. Place the motor reducer gear unit inside the foundation box.
2. Fix the motor reducer in place inside the foundation box by
tightening the 4 nuts.
3. Mount the motor connecting rod on the motor drive shaft and
fix the screw in place using the corresponding self-locking nut.
4. Connect the motor connecting rod to the control rod by
means of the elbow lever.
5. Connect the motor to the control unit, following the
instructions in the following paragraph.

ELECTRICAL CONNECTIONS

VULCAN-230V / VULCAN-120V
YELLOW - GREEN
GND
BLUE
COMMON
BLACK
OPENING / CLOSING
BROWN
CLOSING / OPENING
WARNING: Always connect the earth cable to the
mains power earth system. Use the special fastom shown in
the figure, and a cable with a minimum cross sectional area
2
of 2.5 mm
VULCAN-24V
OPENING / CLOSING
BLUE
BROWN
CLOSING / OPENING
11

Publicité

Table des Matières
loading

Table des Matières