3.
Module status: Proper operation of the LED of wireless communication.
4.
Restart the zone and re-associate it with the system. To do this, press and hold on
up configuration process. Note that, if you need to associate wireless devices, the wireless association module must
be previously open (from SW1 button or from any thermostat, pressing
Think thermostats) .
5.
Restart system: If the system is restarted, this error may be displayed in the thermostats at the beginning of the process.
This message should disappear after around 30 seconds.
AZZBSDAMPERxxR / AZZBSZMRADR
AZZBSZMxxxR
Error 2: Communication error between control board and zone module
(AZZBSDAMPERxx [C/R] / AZZBSZMRAD [C/R] / AZZBSZMxxx [C/R])
This incident blocks the control of the zone. Check this error is not common to all thermostats. If so, verify the proper operation
of the main board. To solve this incident check:
1.
Control board status: Correctly powered.
2.
Control board status: Airzone Connection Bus LEDs are operating properly.
3.
Connection: Verify the polarity of the control board and thermostat connectors.
Wireless module
Fig. 49
Fig. 50
and restart the start-
inside
Advanced Settings
46