Model
DVCX36FP3-3
This conversion kit is to be installed by an Empire Comfort Systems, Inc., distributor (or other
qualified agency¹)* in accordance with the manufacturer's instructions and all codes and
requirements of the authority having jurisdiction. Failure to follow instructions could result
in serious injury or property damage. The qualified agency performing this work assumes
responsibility for this conversion.
National Fuel Gas Code Z223.1 (Latest Edition)
1
*The term "qualified agency" means any individual, firm, corporation or company which either
in person or through a representative is engaged in and is responsible for (a) the installation
of gas piping or (b) the connection, installation repair, or servicing of equipment, who is
experienced in such work, familiar with all precautions required, and has complied with all the
requirements of the authority having jurisdiction.
Perform the safety shutdown test any time work is done on a gas system to avoid the possibility
of fire or explosion with property damage, personal injury or loss of life.
CHECK SAFETY SHUTDOWN SYSTEM
Continuous Ignition Systems (Standing Pilot)
1. Place gas control knob in PILOT position. Main burner should go off and pilot should remain lit.
2. Extinguish pilot flame. Pilot gas flow should stop within 30 seconds. Safety shut-off of pilot gas proves complete
shutdown since safety shutoff valve blocks flow of gas to main burner and pilot.
3. Relight pilot burner and operate system through one complete cycle to make sure all controls operate properly.
Part Description
Pilot Orifice
Main Burner Orifice Front
Main Burner Orifice Rear
SIT Gas Valve Conversion Kit
Gas Conversion Label
Tools Needed: Standard Screwdriver, 1/4" Hex Driver, 5/16" Hex Driver, 3/8" and 7/16" Wrenches
41323-1-0220
GAS CONVERSION INSTRUCTIONS
DIRECT - VENT GAS FIREPLACE
CONVERSION KITS
Part No.
33768
FOR CONVERSION TO PROPANE GAS
CHECK THE SAFETY SHUTDOWN PERFORMANCE
Conversion Kit - 33768
R7658
P321
P208
R7657
1224
Empire Comfort Systems Inc. • Belleville, IL
Model
DVCX42FP3-3
WARNING
WARNING
PARTS LIST
Conversion Kit - 33770
R7658
P320
P208
R7657
1224
Part No.
33770
Quantity Supplied
1
1
1
1
1
Page 1

Publicité

loading

Sommaire des Matières pour Empire Comfort Systems DVCX36FP3-3

  • Page 1 FOR CONVERSION TO PROPANE GAS WARNING This conversion kit is to be installed by an Empire Comfort Systems, Inc., distributor (or other qualified agency¹)* in accordance with the manufacturer’s instructions and all codes and requirements of the authority having jurisdiction. Failure to follow instructions could result in serious injury or property damage.
  • Page 2 12. Pull upward on pilot hood to remove and gain access to pilot injector orifice. If fireplace is not installed or warranty card has not been 13. Remove Natural Gas pilot injector orifice from pilot returned to Empire Comfort Systems, Inc., check off type burner with 5/32" hex (Allen) wrench. of gas converted to on card. Also, indicate conversion by 14. Insert Appropriate Propane Gas pilot injector adding “Conv.” behind type of gas. orifice into pilot burner using the 5/32" hex wrench. 15. Re-install pilot hood to pilot assembly. Push downward to snap in place. Empire Comfort Systems Inc. Belleville, IL If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. www.empirecomfort.com Page 2 41323-1-0220...
  • Page 3 33770 POUR CONVERSION AU GAZ PROPANE AVERTISSEMENT Ce nécessaire de conversion doit être installé par un distributeur Empire Comfort Systems Inc. (ou une agence qualifiée )* conformément aux instructions du fabricant et à tous les codes et exigences de l’autorité ayant juridiction. Le défaut de respecter les directives pourrait résulter en de grave blessure ou dégâts matériels.
  • Page 4 13. Enlever l’orifice de l’injecteur de la veilleuse au Gaz Si le foyer n’est pas installé ou que la carte de garantie n’a Naturel du brûleur de la veilleuse à l’aide d’une clé pas été retournée à Empire Comfort Systems, Inc., cocher hexagonale (Allen) de 5/32 po. le type de gaz converti sur la carte. Indiquer également la 14. Insérer l’orifice approprié d’injecteur de veilleuse conversion en ajoutant « Conv. » derrière le type de gaz. au Gaz Propane dans le brûleur de la veilleuse à l’aide d’une clé hexagonale de 5/32 po. 15. Poser de nouveau la le capot de la veilleuse sur l’ensemble veilleuse. Pousser vers l’avant pour l’enclencher. Empire Comfort Systems Inc. Belleville, IL Pour toute question générale concernant nos produits, veuillez nous envoyer un courriel à info@empirecomfort.com. Pour toute question d’entretien ou de réparation, veuillez communiquer avec votre revendeur. www.empirecomfort.com Page 2 41323-1-0220...

Ce manuel est également adapté pour:

Dvcx42fp3-33376833770