6. APPENDIX

6.1 Electrical diagrams

ENP1MSC
COMP
BLK
CC
CS
RED
L
N
RED BLU
L
N
REMARKS:
1. AT: AIR TEMPERATURE SENSOR
2. COMP: COMPRESSOR
3. CT: EVAPORATOR TEMPERATURE SENSOR
4. EEV: ELECTRONIC EXPANSION VALVE
5. FM: FAN MOTOR
6. FS: WATER PRESENCE DETECTOR
7. HP: HIGH PRESSURE SWITCH
8. IT: WATER INLET TEMPERATURE SENSOR
CR
CS
CR
WHT
C1
4V
P1 P2
OUT2
TC
C2
1
N
3
01
2
4
BLK
BLU
FM
RED
OUT3
OUT1
OUT2
OUT4
OUT5
AC-N
2
2
Controller
12V
FS
LP
9. LP: LOW PRESSURE SWITCH
10. OT: OUTLET WATER TEMPERATURE SENSOR
11. SUT: ASPIRATION TEMPERATURE SENSOR
12. TC: TRANSFORMER 230V~ / 12V~
13. 4V: 4 WAYS VALVE
14. C1: COMPRESSOR CAPACITOR
15. C2: FAN MOTOR CAPACITOR
16. OUT2: DRY CONTACT 7 A MAX
5
7
6
8
EEV
5
GND
AI06
5K
AT
GND
t
AT
AI05
5K
CT
GND
t
CT
AI04
5K
OT
GND
t
OT
AI03
5K
IT
GND
t
IT
AI02
5K
SUT
GND
t
SUT
AI01
+5V
GND
HP
17

Publicité