Wiring to Power Supply
SAFETY WARNING
RISK OF ELECTRICAL SHOCK. THIS RANGE HOOD MUST BE PROPERLY GROUNDED.
MAKE SURE THIS IS DONE BY SPECIALIZED ELECTRICIAN IN ACCORDANCE WITH ALL
APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES. BEFORE CONNECTING
WIRES, SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO
PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY.
Connect the electrical wires.
- If necessary to hide the electrical wire connections, push wires back into the wiring box.
Access the wire connections underneath the hood by removing the bottom casing from
the six screws. Before reattaching the bottom casing, make sure wires do not slip
between motors, impellers, or any moving parts to prevent any damage.
- Connect three wires (black, white and green) to house wires and cap with wire
connectors.
- Connect according to color: black to black, white to white, and green to green.
- Test the operation of the hood before moving on to the next step. Make sure power is
supplied to the hood.
Final Assembly
1.
Turn power ON in control panel. Check all lights and fan operation.
2.
Make sure to leave this manual for the homeowner.