Operation And Maintenance - Simu T5 AUTO+JOB Notice Originale

Masquer les pouces Voir aussi pour T5 AUTO+JOB:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2
Wiring
N
L
PE
- 3 operators (max.) can be wired in parallel on one switch.
- Attach cables to prevent any contact with moving parts.
- If the motor is used outdoors and if the power supply cable is of the H05-VVF type, then run the cable in a UV-resistant conduit,
e.g. trunking.
- The motor does not allow connection with an emergency power supply such as regulated power supply or power generating unit.
3
Power up of the operator
>>
After the first two consecutive and complete opening and closing of the shutter:
- The motor memorizes automatically the end limit ( up and down) positions.
- The «stop on obstacle» function is activated.
It is advised to carry out these two opening / closing cycles as soon as the product is installed.
4
Cancelling the automatic settings
In the case of a new installation with this operator, it is advised to reset the motor according to the following procedure:
- Press 3 consecutive times, for 1s. each time, on the UP key. The motor runs briefly at each press.
- Press 3 consecutive times on the DOWN key. The first two press for 1s. (the motor runs briefly at each press) and the third press for
2s. The motor runs twice in the same direction.
>>
>>
1 s
1 s
5

Operation and maintenance

This drive is maintenance-free.
- Press the ▲ button on the control point to lower the motorised product.
- Press the ▼ button on the control point to raise the motorised product.
Tips and recommendations for use:
Observations
The motorised product does not operate.
- If the motorised product still does not work, contact a drive and home automation professional.
SIMU hereby declares that the drive covered by these instructions, when marked for input voltage 230V~50Hz and used as intended according to these instructions,
is in compliance with the essential requirements of Directives 2006/42/EC and 2014/30/EU. A declaration of conformity detailing the standards and specifications
used and stating all particulars for identification of the drive, name and address of the person(s) authorised to compile the technical file and empowered to draw up
the declaration including place and date of issue is available at www.simu.com
2/2
2
3
1
230V ~ 50 Hz
>>
>>
1 s
Possibles causes
The drive is in thermal protection.
1
2
2
T5 AUTO+JOB
>>
>>
>>
1 s
1 s
Wait until the motor cools down.
9910013
9910014
Blue
Brown
Black
Green/Yellow
>>
>>
Solutions
1
>>
>>
2 s

Publicité

Table des Matières
loading

Table des Matières