Venturi Adjustment; Flame Characteristics; Restricting Vertical Vents - Napoleon BGD40GN Instructions D'installation Et D'utilisation

Table des Matières

Publicité

10.1.1

VENTURI ADJUSTMENT

This appliance has an air shutter that has been factory set open according
to the chart below:
Regardless of venturi orientation, closing the air shutter will cause a more
yellow flame, but can lead to carboning. Opening the air shutter will cause a
more blue flame, but can cause flame lifting from the burner ports. The
flame may not appear yellow immediately; allow 15 to 30 minutes for the
final flame colour to be established.
AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED
INSTALLER!
BGD40G
NG
1/8"
LP
5/16"

10.2 FLAME CHARACTERISTICS

f i r e - p a r t s . c o m
It's important to periodically perform a visual check of the pilot and burner fl ames. Compare them to the
illustration provided. If any fl ames appear abnormal call a service person.

10.3 RESTRICTING VERTICAL VENTS

Vertical installations may display a very active fl ame. If this appearance is not desirable, the vent exit must
be restricted using a restrictor vent kit. Refer to "ACCESORIES" in the "REPLACEMENTS" section for the
appropriate kit. This will reduce the velocity of the exhaust gases, slowing down the fl ame pattern and creating
a more traditional gentle fl ame appearance. Specifi c instructions are included with the kit.
All manuals and user guides at all-guides.com
VENTURI
BURNER
ORIFICE
49.1
PILOT
BURNER
ELECTRODE
FLAME
SENSOR
FLAME MUST ENVELOP
UPPER 3/8" TO 1/2" OF
FLAME SENSOR
54.1A
77.3
W415-1028 / A / 08.13.12
37
AIR
SHUTTER