Hard Wiring Connection; Receptacle Wiring Diagram - Napoleon BGD40GN Instructions D'installation Et D'utilisation

Table des Matières

Publicité

8.1

HARD WIRING CONNECTION

It is necessary to hard wire this appliance.
Permanently framing the appliance with an enclosure, requires the appliance junction box to be hard wired.
This appliance must be electrically connected and grounded in accordance with local codes. In the absence
of local codes, use the current CSA C22.1 Canadian electrical code in Canada or the ANSI/NFPA 70-1996
national electrical code in the United States.
8.2

RECEPTACLE WIRING DIAGRAM

f i r e - p a r t s . c o m
Remove the two screws that secure the junction box assembly to the outer shell on the left side of the
A.
appliance and remove the junction box assembly.
Remove the one screw that secures the junction box to the junction box plate and slide off the clip.
B.
Route the supply wire through the 7/8" hole of the junction box plate with a box connector (not
C.
supplied).
Connect the 120 volt supply wire to the receptacle as per the CSA C22.1 Canadian Electrical Code in
D.
Canada or the ANSI/NFPA 70-1996 National Electrical Code in the United States.
Once the wiring is complete, re-install the junction box to the junction box plate and re-secure the
E.
screw that was previously removed.
Re-install the junction box assembly by reversing step A.
F.
All manuals and user guides at all-guides.com
SWITCH HOUSING
(C/W 2 RECEPTACLES)
L1
WIRE NUTS
L2
(C/W GROUND SCREW)
CABLE
CONNECTOR
ELECTRICAL
BOX COVER
W415-1028 / A / 08.13.12
33

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bgd40gp

Table des Matières