3-1-3-5. Power saving load
Model
SE200 / SE350
SE400
3-2. Rear Panel Introduction
Model
3-2-1. DC Input Terminal
The DC cables should be as short as possible (less than 6 feet / 1.8
meters ideally)
The size of the cable should be thick enough to limit the voltage
drop to less than 2% when carrying the maximum input current to
prevent frequent low-input voltage warnings, and shutdown.
The following sizes of cables and fuses are recommended distance
(<6 ft.) between the batteries and the inverter.
SE200-112 / 212
SE200-124 / 224
SE350-112 / 212
16
Input Saving Power
<10VA
<20A
Table 14. SE series power saving load
Figure 8. SE series rear panel view
SE Series Rear Panel
DC Input Terminal
Green Terminal
Remote Port (RJ-11)
Chassis Ground
Table 15. SE series rear panel introduction
Model
Wire AWG
#10
#14
#8
Saving Wake up
>15VA
>30 VA
Inline fuse
≧30 A
≧15 A
≧50A