THERE ARE 3 DIFFERENT AIR QUALITY MODES AVAILABLE FOR VIEWING
1.
Out
This number is the amount of air particles detected in the filtered air exiting the air purifier.
In
This number is the amount of air particles coming into the unit from the ambient air. These have not been directly
filtered yet.
1.
This screen displays a total snapshot of your room air quality.
The top section of the screen gives you a graphical representation of your current room air quality. The graphical display
is based on the PM2.5 IN readings (from the PM2.5 screen) of the room's air that is entering the unit.
Room Air Quality:
If PM2.5 = 0 - 12 µg/m3, it will display "CLEAN" inside of a blue graphic.
If PM2.5 = 12.1 - 35.4 µg/m3, it will display "CLEANING" inside of a yellow graphic.
If PM2.5 = - 35.5+ µg/m3, it will display "CLEANING" inside of a red graphic.
The middle section of the screen displays the current cleaning efficiency which calculates the percentage reduction of
PM2.5 particulate matter coming out of the purifier vs. PM2.5 particulate matter coming in. The PM2.5 readings refer
to atmospheric particulate matter that have a diameter of 2.5 µm and smaller (example viruses, bacteria and smoke).
2. PM2.5
- Displays particle density (ug/m^3 or mass per volume) of particle sizes 2.5 um and smaller (example
viruses, bacteria and smoke). This air quality status displayed is related to the United States EPA's AQI (Air Quality Index).
For more information, please visit http://www.airnow.gov.
If the particle reading is between 0 – 12, it displays a CLEAN measurement in blue.
If the particle reading is between 12.1 – 35.4, then it displays a FAIR measurement in yellow.
If the particle reading is 35.5+ or more, then it displays a POOR measurement in red.
3. PM10
Displays particle density (ug/m^3 or mass per volume) of particles sizes 10 um and smaller (for example
-
pollen, dust, smoke, allergens and viruses). The air quality status displayed is related to the United States EPA's AQI (Air
Quality Index). For more information, please visit http://www.airnow.gov.
If the particle reading is between 0 – 54, it displays a CLEAN measurement in blue.
If the particle reading is between 55 – 154, then it displays a FAIR measurement in yellow.
If the particle reading is 155+ or more, then it displays a POOR measurement in red.