General Specifications; Electrical Specifications - Wavetek Meterman 220 Manuel D'utilisation

Table des Matières

Publicité

F • Accessoires en Option
DL243C
Cordons de mesure standards
DL248C
Cordons de mesure Deluxe (900°C/1652°F)
TL245
Cordons de mesure de rechange
CT231A
Pince de courant CA 150A fibre optique
CT232A
Pince de courant CA 1000A
CT234A
Pince de courant CA 400A
instrument sans gaine
CT235
Pince de courant CA/CC1000A

General Specifications

Display: 3-3/4 digit LCD, 4300 counts,
with annunciators and menu features.
Polarity Indication: Automatic
Input overload indication: I.OL.
Low Battery Indication:
hours battery life remain, accuracy is no
longer guaranteed
Display Update Rate: 2/sec, nominal.
Oper. Temp.: (0 - 80% R.H. non-condensing):
0°C to +50°C
Storage Temp: -20°C to 40°C, 0 to 80%
R.H. non-condensing, battery removed
Temperature coefficient: 0.1 x (spec. accu-
racy)/°C (0°C to18°C or 28°C to 50°C)
Fusing: 0.5A/500V; I.R. 10kA15A/600V;
I.R.100kA
Power: Standard 9-volt battery, NEDA 1604,
JIS 006P, IEC 6F22
Auto Power-Down: Meter powers down after
approx. 30 minutes of inactivity or
APD Display. Not in Min/Max function.
Battery Life (typical): 300 hours, alkaline.
Backlight usage consumes extra power and
will decrease battery life significantly.
Backlight auto-off after approx. 60
seconds.
Dimensions, without holster (H x W x D): 7.2"
x 3.3" x 1.9", (183x84x47 mm)
Weight (incl. battery): 484 g (17.1 oz)
Accessories: Test leads, spare 0.5A/500V
fuse*, battery*, and Operator's Manual
Case material: Flame retardant, high-impact
thermoplastic
SPECIFICATIONS
; less than 50
* in instrument
- 29 -
VC231
Sacoche en vinyl rembourrée pour
CT236A
Pince de courant CA 500A (sortie mV)
instrument avec gaine.
CT237
Pince de courant CA/CC 200A
CT238
Pince de courant CA/CC 20A
RF241
Sonde RF 650MHz
TC 253
Convertisseur Température/Tension
VC221A
Sacoche en vinyl rembourrée pour
Safety: Meets EN61010-1 Cat II - 1000V; Cat
III - 600V. Pollution degree 2.EMC: Meets
EN55011 and EN61000-4-8
EMC: This product complies
with requirements of the
following European Community
Directives: 89/336/EEC (Electromagnetic
Compatibility) and 73/23/EEC (Low
Voltage) as amended by 93/68/EEC (CE
Marking).However, electrical noise or
intense electromagnetic fields in the
vicinity of the equipment may disturb the
measurement circuit. Measuring
instruments will also respond to unwanted
signals that may be present within the
measurement circuit. Users should
exercise care and take appropriate
precautions to avoid misleading results
when making measurements in the
presence of electronic interference.

Electrical Specifications

Accuracies at 23°C ±5°C, <80% RH non-
condensing, guaranteed for one year
DC Volts
Ranges: 430mV, 4.3, 43, 430, 1000V
Resolution: 100µV in 430mV range
Accuracy: All Ranges ±(0.25% rdg +2dgts)
Input Impedance: 10MΩ
CMRR: >120dB up to 1000V NMRR: >60dB
at 50 or 60Hz OL Protection: 1000VDC or
Peak AC Transient protection: 6kV.
AC Volts
Ranges: 430mV, 4.3, 43, 430, 750V
Accuracy (%rdg + dgt)

Publicité