MASTER STATION WITH TFT DISPLAY
TECHNICAL SPECIFICATIONS
Compliance with European standards
•
Security rules according to norm EN 60950
•
CEM transmission according to norm EN
55022 class B
•
CEM immunity according to norm EN 55024
Mechanical properties
•
Protection IP40 degree according to EN 60529
•
ABS case with wall suspension
•
Case dimensions: H 255mm x L 127mm x Ep.
47 mm
•
Weight : 550g
•
ZAMAC base
•
Dimensions with base: H 255 x L 127mm x P
155mm.
•
Total weight: 1kg
General electrical properties
•
Protection class 3 against electric shocks
according to EN 60950.
•
Storage temperature: -20° / +70°C.
•
Operating temperature: 0 à +50°C.
•
Power supply: 15VDC (15V à 30V).
•
Consumption: 15V/150mA off and 15V/200mA
on
Button
•
Speed acquisition: 5Hz (200ms)
Input
•
1 protected and filtered TOR input
•
Speed acquisition: 5Hz (200ms)
Ouput
•
Voltage free relay output
•
24VAC/DC 5A relay cut power
•
Maximum
frequency
commutation time: 200ms)
Environmental protection:
Dispose of this product in compliance with environmental preservation regulations.
Datasheet n° 604-0001L
Non-binding photos and document. In constantly striving for improvement, the CASTEL company reserves the right to make any modifications it considers necessary.
is
5 Hz
(Minimum
CASTEL : ZAC de la Ronde – 10 route du Bois de la Casse - 49680 NEUILLE– France
Tél. : (+33) 02.41.40.41.40 - Fax : (+33) 02.41.40.41.49
Display screen
•
TFT colour touch screen 4.3"
Camera
•
CMOS 1/6'' 640*480
Audio Codec
•
G711 Ulaw/Alaw
•
GSM
•
G722
Video Codec
•
Video format CIF/QCIF
•
H263
•
H263-1998
•
H264
DTMF
•
RFC-2833
•
SIP INFO
Ethernet network 10/100 Mbit
•
IP static or DHCP
•
POE class 2, conforms with IEEE 802.3af
standard
•
In option: Wi-Fi wireless network in conformity
with IEEE 802.11b/g standard
•
Secure Ethernet connection using the 802.1X
protocol (Radius)
•
SNMP V1 & V2c
Handset (in option)
•
Induction loop for hard of hearing people
www.castel.fr
FR
EN