MASTER STATION WITH TFT DISPLAY
Functions of the logical input (or flags)
Logical input allows 2 kinds of functionality:
Create a logic from which it will be possible to condition actions in relations
Create a counter which will be updated as events and depending on the value of this counter start one or
more actions if required.
Logical relations configuration
The web server is the start point to configure automatism also called relations.
There are two kinds of relations:
Schedule: can start actions on identified time slots. There is 3 priority levels for a schedule relation (high,
medium, small)
Logical :
↘ Logical condition: can start actions depending on the status.
A logical relation can be integrated by some operator as AND, OR, NOT, XOR. In the same way, a
logical relation can start several actions.
↘ Numerical condition: can perform actions by comparing the value of a counter with various thresholds.
It is also possible to add or subtract counter values and compare the results.
Configuration of the user of the web server (software users)
The web server allows granting, modifying or deleting privileges to users by specifying their login, password and
operating language.
Configuration of the call users
The web server allows creating, importing or deleting user phone which is attributed a profile. Therefore a user can log
into the station via a user name and password then activate his profile on the station.
Configuration of the profiles
It's possible to create modify or delete functional profile of the station. Each profile specify a priority of the station, a
configuration of the buttons functions, a configuration of the directory (black list/white list) and security right of station.
The station can operate with a single profile or various profiles according to time slots or according to a user log on the
station.
Configuration of the phone book
It is possible to create, modify or delete entries in the phone book of the station.
It is possible to create entries for single calls or for multiple calls.
Configuration of the local access
The station can be used to control the access.
↘ Programmation of 1 to 15000 access codes with 1 to 20 numbers.
↘ Programmation of action(s) linked to the access authorization or access refused using logical relations
↘ Taking into account of time slot
↘ A message on the screen allows visualizing the authorisation or the refused of the access.
Administration management SNMP
The station includes an agent SNMP (Simple Network Management Protocol) to respond to SNMP requests and to
send notifications (traps) to a SNMP manager.
From web pages, you can:
✓ Configure different community (read / write)
✓ Configure system data ("sysContact" and "sysLocation")
✓ Configure notifications (recipient, community ...)
✓ Download "MIB Castel"
It supports SNMPv1 and SNMPv2c versions.
Autotest functions
The station has several tests to validate its functioning:
✓ Autotest "Micro and speaker": to test the remote operation of speakers and microphone. From the page
"Advanced Settings", it is possible to adjust levels of the test following the installation environment. This
test can be triggered from the web server or an SNMP command. The test result is visible through the
history of the web server and an SNMP notification.
✓ Autotest "keys": the detection of a blocked mechanical button (contact for over 20s) is indicated by an
SNMP notification and an event is reported in the history of the web server.