9. Remove bolts holding skid to upper section back and close holes with supplied plugs.
10. Position upper section over lower section.
Caution: Follow steps 11-14 to anchor upper and lower sections of all two-section upright bins. Bracket must be
installed to avoid possible injury should unit move.
11. Lower upper section onto lower section, taking care not to disturb gaskets and sealant beads.
12. Install icemaker according to manufacturer's instructions.
13. From inside bin (access can be gained through lower door assembly) seal entire perimeter of seam between upper
and lower sections with General Electric RTV 180 sealant provided (see figures below).
Caution: Completely cover gasket materials with sealant. Failure to properly seal sections may result in leakage
and/or ice contamination and will void warranty.
14. Install supplied screws on side H-brackets and tighten, then seal entire perimeter of H-bracket with silastic.
15. Insert long side of each plastic inspection window in upper track of opening and push in to seat.
16. Remove any remaining protective plastic or temporary fastenings from doors and outside of bin.
17. Connect drain line to 1" FPT female fitting located in bottom of bin.
18. Make final connections to icemaker.
Cross section – side view
bin exterior
bead of sealant
screw
H-bracket
Installing icemaker drain
Required for some icemakers only. For these machines Follett predrills hole and provides 3/4" straight threaded drain fitting
to be installed through hole. To install fitting:
1. Remove plastic nut on fitting.
2. From inside (liner side) bin, insert threaded portion through hole provided in side of bin.
3. Replace plastic nut on threaded portion and tighten against outside of bin.
4. Connect supplied tubing to icemaker drain connection after installing icemaker.
bin interior
upper section
lower section
Bin cutaway
Entire inside upper
and lower section
seam and entire
perimeter of H-bracket
must be sealed with
silastic provided