Fireplace Installation
I n - w a l l
Installation - 100mm Deep
CAUTION: Two people may
be required for various steps of
this procedure.
1. Prepare a wall with a framed
opening of 118.1 cm wide x 42
cm high (Figure 4).
!
NOTE: The sizing has allowed
for 6.4mm around the fireplace
insert for ease of installation. this
fireplace does not require any
additional venting.
2. Choose
supplying power to the unit:
• Plug in (you may run the
power cord out of the framed
wall opening to an existing
outlet or install an outlet on
a nearby wall stud within the
wall).
• Hard wire the fireplace.
!
NOTE: Hard wiring can be done
by removing the plug from the
factory fitted cord and completing
the wiring according to national and
Local elecrical Codes.
WARNINg: Do not attempt to
wire your own new outlets or circuits.
to reduce the risk of fire, electric
shock or injury to persons, always
use a licensed electrician.
R e c e s s e d
your
method
Figure 4