Delivery Includes; Ordering Code; Dimensions - saia-burgess CXE 322 Notice De Mise En Service

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Output 2:
Relay with potentialfree change-over
contact
switching voltage max. 250 VAC / 300 VDC
switching current max. 3 A
switching current for DC min. 30 mA
switching performance max. 50 W for
DC and max. 2000 VA for AC
or
optocoupler with open collector and emitter
switching performance: 30 VDC / 15 mA
Ucesat at I
= 15 mA: max. 2.0 V
c
Ucesat at I
= 5 mA: max. 0.4 V
c
Responding time of outputs:
Relay:
approx. 6 ms
Optocoupler: approx. 1 ms
Data retention:
min. 10 years or 10
Transmitter voltage:
24 VDC –40% / +15%, 80 mA
unstabilized for AC-versions
for option "backlit LCD"
24 VDC –40% / +15% 60mA
unstabilized
Fuse protection:
recommended fuse
for DC:
0,125 AT
for 230 VAC: 0,05 AT
for 115 VAC: 0,1 AT
for 48 VAC: 0,2 AT
for 24 VAC: 0,4 AT
Noise immunity:
EN 55011 class B and EN 50082-2
with shielded data inputs
Ambient temperature:
0...50°C

Dimensions:

panel cut-out 45 x 45 mm
with front frame No. 2
panel cut-out 50 x 50 mm
16
Storage temperature:
Weight:
Protection: IP 65 (front)
Colour of housing:
Cleaning:

11. Delivery includes

– Counter CXE
– Screw terminal plug 7 poles, reference grid 5.08 mm
– Screw terminal plug 7 poles, reference grid 3.81mm
6
– Bezel for screw mount, panel cut-out 50 x 50mm
memory cycles
– Bezel for clip mount, panel cut-out 50 x 50 mm
– Bezel for clip mount, panel cut-out 45 x 45 mm
– Panel mounting clip

12. Ordering Code

with front frame N0. 3
–25°C...+70°C
approx. 240 g (AC-version with relay)
brown
The front of the unit is only to be cleaned
with a soft and wet (water!) cloth.
CXE 322: 11 ... 30 V DC
CXE 822: 90 ... 260 V AC
panel cut-out 50 x 50 mm

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cxe 822

Table des Matières