Troubleshooting
Fault
Appliance does not
do anything
Appliance does
not reach the set
temperature.
If after these controls, the malfunctioning continues, it is advisable to contact technical assistance.
In case of any doubt, always contact your supplier!
Technical specification
Item no.
Operating voltage and frequency
Rated power
Protection class
EN
Waterproof protection class
Temperature range
Capacity
Dimensions
Net weight (approx.)
Item no.
Operating voltage and frequency
Rated power
Protection class
Waterproof protection class
Temperature range
Capacity
Dimensions
Net weight (approx.)
Remarks: Technical specification is subjected to change without prior notification.
8
Symptom
Possible cause
No mains voltage
Hi-limiter (thermal cut-out)
Orange light
tripped.
doesn't light
Hi-limiter (thermal cut-out)
defective
Thermostat defective
Thermostat defective
Long frying time.
Element defective
205808
3000W
4L
217x380x
(H)300mm
5kg
975404
230V~ 50Hz
2200W
Class I
IPX3
50-190°C
4L
217x380x
(H)300mm
5kg
205815
205822
230V~ 50Hz
3300W
3500W
Class I
IPX3
50-190°C
6L
8L
265x430x
265x430x
(H)290mm
(H)345mm
5.4kg
6kg
975428
3500W
8L
265x430x
(H)345mm
6kg
Possible solution
Check the electrical installation.
Switch light defective
Reset the Hi-limiter (thermal cut-out) (See
RESET on page 6)
Contact your supplier
Contact your supplier
Contact your supplier
Contact your supplier
205839
205846
3500W x 2
3000W x 2
8L x 2
4L x 2
550x430x
470x420x
(H)345mm
(H)330mm
11kg
8.5kg
205853
3300W x 2
6L x 2
550x430x
(H)290mm
9.5kg

Publicité