Switching functions
The outputs 1 and 2 can be set separately as normally open / normal-
ly closed, output 2 can also be configured as 4...20 mA analogue out-
put.
Analogue output
(only output 2)
Switching function
(output 1 and output 2;
function can be set
separately per output)
Switching logic (applies to both
switching outputs)

Electrical connection

The unit must only be connected by a skilled electrician. The
national and international regulations for the installation of elec-
trical equipment must be adhered to.
Voltage supply to EN50178, SELV, PELV.
Disconnect power before connecting the unit.
2 x p-switching
1
2
4
2: OUT2
3
4: OUT1
Core colours of ifm sockets:
1 = BN (brown), 2 = WH (white), 3 = BU (blue), 4 = BK (black).
18
All manuals and user guides at all-guides.com
BN
L +
WH
BK
BU
L
Output 1
normally open (Hno)
normally closed (Hnc)
p-switching (PnP)
1 x p-switching / 1 x analogue
1
BN
2
WH
4
BK
2: OUT2
3
BU
4: OUT1
Output 2
I: 4 ... 20 mA
L +
L