Safety Precaution - VESTEL AC22 Serie Directives D'installation

Masquer les pouces Voir aussi pour AC22 Serie:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

SAFETY PRECAUTION

CAUTION
RISK OF ELECTRIC SHOCK:
CAUTION:
VESTEL ELECTRIC VEHICLE CHARGER STATION SHALL
BE MOUNTED BY A LICENSED OR AN EXPERIENCED
ELECTRICIAN IN ALIGN WITH ANY REGIONAL OR
NATIONAL ELECTRIC REGULATIONS AND STANDARDS IN
EFFECT.
Warnings
1- WARNING: Danger of injury or electric shock. Prior to connecting EV charger electric supply, disconnect
the power on AC mains side or the load centre.
2) On the AC mains side of Vestel EV charger, the Circuit Breaker, Leaking Current Relay
and AC mains cable combination must be used.
3) EV charger AC grid connection and load planning shall be reviewed and approved by
authorities as specified by the regional or national electric regulations and standards in
effect. For multiple EV charger installations the load plan shall be evaluated accordingly.
The manufacturer shall not be held liable for any reason whatsoever in the event of damages and risks that
are borne of errors due to AC grid supply connection and load planning.
AC22 Series
Built-in Residual Current Sensing module
Electric Infrastructure Requirements
Required Circuit Breaker on AC Grid
Required RCCB on AC Grid
Required AC Grid Cord
Vehicle charger Compatibility
AC11 Series
Built-in Residual Current Sensing module
Electric Infrastructure Requirements
Required Circuit Breaker on AC Grid
Required RCCB on AC Grid
Required AC Grid Cord
Vehicle charger Compatibility
DC 6mA
400VAC 50/60 Hz - 3-phase 32A
4P-40A MCB Type-C
40A - 30mA RCCB Type-A
5 x 6mm² (< 50m)
External Dimensions: Ø 15-21 mm
Type -2
DC 6mA
400VAC 50/60 Hz - 3-phase 16A
4P-20A MCB Type-C
20A - 30mA RCCB Type-A
5 x 4mm2 (< 50m)
External Dimensions: Ø 15-21 mm
Type -2