5- As specified in Figure 5, connect the AC cable to electric socket.
AC mains must be connected to L1, L2, L3, Neutral and Ground cables as specified in Table 2.
Figure 5
Electric Clamp
AC Cable Colour
1
Ground (Green-Yellow)
2
AC L1 (Brown)
3
AC L2 (Black)
4
AC L3 (White)
5
AC Neutral (Blue)
Table 2
English - 5 -