Configuración de serie = 3333 (IA1 + IA4 on; IA2 + IA5 on; IA3 + IA6 on; QA1 + QA2 on)
es
X X X X
X: 0 - 10 V entradas analógicas IA1 + IA4:
0 = ambas off; 1 = IA1 on; 2 = IA4 on; 3 = IA1 + IA4 on
X: 0-20 mA entradas analógicas IA2 + IA5:
0 = ambas off; 1 = IA2 on; 2 = IA5 on; 3 = IA2 + IA5 on
X: entradas del sensor de resistencia PT100 IA3 + IA6
0 = ambas off; 1 = IA3 on; 2 = IA6 on; 3 = IA3 + IA6 on
X: salidas analógicas QA1 + QA2
0 = ambas off; 1 = QA1 on; 2 = QA2 on; 3 = QA1 + QA2 on
Merker-Belegung – Marker assignment – Affectation des mémoires – Przyporzadkowanie oznaczen –
Ocupación de marcas
EASY8..., MFD-CP8-...
EASY406-DC-ME
IA1
MW93
IA2
MW94
IA3
IA4
IA5
IA6
QA1
MW95
QA2
EC4P-...
EASY406-DC-ME
IA1
MW184
IA2
MW186
IA3
IA4
IA5
IA6
QA1
MW188
QA2
8/12
EASY411-DC-ME
MW89
MW91
MW93
MW90
MW92
MW94
MW95
MW96
EASY411-DC-ME
MW176
MW180
MW184
MW178
MW182
MW186
MW188
MW190

Publicité