Chap. 5. Maintenance, Breaks Research And Cleaning - Diamond TS 12 Manuel D'utilisation

Masquer les pouces Voir aussi pour TS 12:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 57

CHAP. 5. MAINTENANCE, BREAKS RESEARCH AND CLEANING

MAINTENANCE MAN REQUIREMENTS
With the term "maintenance" must not be understood only the periodical check of the machine normal functioning but also
the analysis and the consequent remedy of all causes that for any matter put it out of service. It is absolutely necessary that for
the maintenance, cleaning, parts change and breaks research activities performed from the user, this work is entrusted to
skilled personnel, competence and authorized from the employer.
All operations of maintenance, cleaning and parts change, none excluded, must be definitely performed with the machine
completely stopped and insulated from the external feeding sources.
MAINTENANCE PRESCRIPTIONS
PROTECTIONS REMOVAL AND/OR PROTECTION DEVICES
For any interventions described in the present chapter, it is necessary to remove from their position some fixed
protections.
The removal can happen only from the maintenance man.
At the end of the interventions, these protections must be replaced and blocked in their original position, with the fastening
systems which were foreseen before the intervention.
The maintenance responsible must disconnect completely the machine, as here follow reported, before to proceed with the
removal of a fixed protection and/or with the element change.
INSULATION FROM THE EXTERNAL FEEDING SOURCES
Before to perform any operation of maintenance, cleaning and parts change, the external feeding sources must be sectioned
and insulated.
Position on "zero" the protection device placed upstream of the
electric equipment feeding line.
BREAKS OR DAMAGES RESEARCH AND MOVING ELEMENTS UNBLOCKING
Here follow are indicate the interventions for the breaks or damages research and moving elements unblocking which can
be performed from maintenance men.
TYPE
POTENTIAL CAUSE/S
General Black out
Net voltage
Fuses or magneto thermals intervention
lacking
place upstream of the machine feeding
line
Protection device intervention inside the
Functioning
machine
intervention
Cause/s not identifiable
Feeding voltage lacking.
Hopper not inserted or bad positioned
only on model TI 32R
The machine
Sectioning devices set on "OFF".
doesn't
function: the
Intervened fuses or not functioning
Archimedean
magneto thermals.
screw doesn't
rotate
Lacked running button functioning
Thermal intervention due to the
overheating
Disconnect the general sectioning device and provide to
protect the plug with proper systems
MODALITY AND COMPARISONS
Contact the electric energy distributor
After having eliminated the causes that have determined the protection device
intervention, restore it. In case of problem persistency contact an electrician
technician.
Contact an electrician technician: after having eliminated the causes that have
determined the protection device intervention, restore it.
In case of fuses intervention, change them with types of the same model,
calibration and intervention curve.
Contact directly the Authorized Assistance Center
Check and restore the electric energy.
Insert or reposition the hopper
Turn the sectioning devcies in the position "ON"
Change the intervened fuses, check the magneto thermal switches state.
Check the START button efficiency and eventually contact directly the Authorized
Assistance Center.
Wait the complete cooling before the machine restarting
Pag.
di
14
18

Publicité

Table des Matières
loading

Table des Matières