• Make sure to rest your arm and
move it so that the device is
at heart level (see image). An
O.K. symbol was integrated
into the device to additionally
assist you. It signals the
correct position of the blood
pressure monitor. You are in the right position if all you
can see on the display is O.K.
• Please make sure to have a 5 –10 minute period of rest
before measurement.
• Switch on the blood pressure monitor with the start/stop
button
.
• After the self test, during which all display elements are
briefly displayed, measurement begins. The pressure is
increased to 190 mmHg. If this pressure is insufficient, the
device automatically pumps an extra 30 mmHG (Fuzzy
Logic).
• When the measurement has been taken, the remaining air
pressure dissipates very quickly. It displays pulse, systolic
and diastolic blood pressure as well as the resting indicator
(see Chapter 5.4).
• Now use the M1 and M2 memory buttons to select the
desired user memory. If you do not select a user memory,
the measurement is stored in the most recently used user
memory. The relevant symbol "M1" or "M2" appears in
the display.
All manuals and user guides at all-guides.com
• • • • • • • • • • • • •
• Using the start/stop button,
sure monitor. The measurement is then stored in the
selected user memory. If you forget to turn off the device,
it will switch off automatically after approx. 3 minutes.
In this case too, the value is stored in the selected user
memory.
• You can interrupt measurement at any time by pressing
the start/stop button
taking another measurement!

5.3 Evaluating results

Cardiac arrhythmia:
This instrument can identify possible cardiac arrhythmia dis-
orders during measurement and if necessary indicates the
measurement with the flashing icon
This may be an indicator for arrhythmia. Arrhythmia is a
condition where the heart rhythm is abnormal as a result of
defects in the bioelectrical system controlling the heart beat.
The symptoms (omitted or premature heart beats, slow or ex-
cessively fast heart rate) may be caused, among other things,
by heart disease, age, physical predisposition, excessive use
of stimulants, stress or lack of sleep. Arrhythmia can only be
ascertained through examination by your doctor. Repeat the
measurement if the flashing icon
measurement. Please note that you should rest for 5 minutes
between measurements and not talk or move during the
measurement. If the icon
16
switch off the blood pres-
. Wait at least 5 minutes before
.
is displayed after the
appears often, please contact