STEP 4
• Connect all gas connections on the range
or slide-in and tighten according to the
appropriate RV and gas codes.
I
All openings in the cabinetry around the gas
line must be closed at the time of installation.
STEP 6
• Turn on the gas supply.
• Conduct the range or slide-in leak testing:
• Loosen the leak check fitting screw on the regulator by one turn.
• Place the gauge on the fitting.
• Check for leaks:
– Leak testing shall be conducted according to the manufacturer's instructions.
– Use a non-corrosive leak detection fluid. Do not use soap and water.
– Leak tests in excess of 0.5 PSI of air pressure will invalidate warranty.
• Retighten the leak check fitting screw upon completion of the leak test.
• Conduct the range or slide-in gas pressure testing prior to operation.
I
When conducting the range or slide-in gas pressure testing prior to operation:
• The range or slide‑in, and any individual shut‑off valves, must be disconnected from the gas supply piping
system when pressure testing the system at pressures exceeding 0.5 PSI.
• The gas supply pressure for checking the regulator setting shall be at least 1 in. W.C. (249 Pa) above the
manufacturer's specified manifold pressure. The maximum gas supply pressure is 14 in. W.C.
• Turn off the gas supply.
9
STEP 5
Gas Connection
• Secure the range or slide-in by placing wood
Screw
screws (not provided) through the designated
holes and into the cabinet. Do not force the
mounting flanges to bend.
Screw
Regulator
RANGE AND SLIDE-IN