4. Set the required temperature
The temperature can be set from +41°F/+5°C to +86°F/+30°C in steps of 1,0°F/0.5°C. Warm water is always available
(122°F/50°C) when the boiler is on and running on LPG and/or electricity. During summer, when only warm water is
required, adjust the temperature setting to well below the surrounding temperature so that central heating circulation is
not called for.
72°F
2
Off
ON
On
5. Extra hot water
If you need more hot water, you can raise the water temperature temporarily from 122°F/50°C to 149°F/65°C. After 30
minutes, the boiler reverts to normal operation. When you have selected more hot water the circulation pump stops.
72°F
2
ON
Off
On
If you wish to revert to the basic hot water settings before 30 minutes have expired.
72°F
2
ON
Off
On
12
1. The temperature displayed is
the temperature which is set
at present (in this case 72°F
/22.0°C).
2. R aise the temperature by
pressing the + button. Lower
the temperature by pressing
the – button.
3. The settings are ready and the
central heating will circulate at
the set temperature.
1. I ncrease the quantity of hot
water by pressing the + button.
When activated the plus sym-
bol changes color to green.
2. The settings are ready.
1. R eset the hot water by press-
ing the – button.
2. The settings are ready.