English
Keys to the figures:
Installation and operating instructions
General keys
1
Cistern
2
Float switch
3
Floating extractor
4
Filter
5
Suction line
6
Public water supply
7
Switchgear RainControl Basic (RCB)
8
3-way valve
9
Pressure and flow controller Ecocontrol
9a
Display (mains on/ power on)
9b
Display (Pump in operation/ Pump on)
9C
Display (fault)
9D
Commissioning- and fault acknowledgement
button RESET
9E
Neutral conductor pump
9F
Phase pump + return signal RCB
9G
Earthing pump
9 h
Earthing RCB
9 I
Neutral conductor RCB
9 k
Phase RCB
10
Pump
11
Connection of the overflow (DN75)
12
Connected load on pressure side
13
Additional earthing
14
AF Basic
15
Cap
16
DN25 - G1" connection suction line
17
Rp 1" connection on the pressure side
18
G 3/4" connection to public water supply
19
Overflow
20
Connecting cable to power supply
(length: 1.80 m)
21
Filling the pump
22
Replenishment reservoir (11 l)
12
Fig. 3
PE
Earthing
X1
L
Phase
N
Neutral conductor
N
Neutral conductor additional pump
L1
Phase additional pump
x2
1
Pressure and flow controller Ecocontrol L
2
Pressure and flow controller Ecocontrol N
3
Pressure and flow controller Ecocontrol U
x2
4
3-way valve feed mode
5
3-way valve neutral conductor
6
3-way-valve rainwater operation
X4
S1
2 contacts for float switches
Supply voltage 5 V DC
S1 – contact opened – potential-free (0 V)
NOTE:
Contact closed means
(signal for) cistern operation
X4
S2
2 contacts for overflow level
S2 – factory-bridged
S2 – Contact opened – potential-free (0 V)
NOTE:
Contact opened means (signal for)
overflow replenishment reservoir