WORKING HINTS FOR YOUR
TOOL
If your power tool becomes too hot, especially
when used at low speed, set the speed to
maximum and run it with no load for 2-3
minutes to cool the motor. Avoid prolonged
usage at very low speeds. Always keep the
blade sharp.
Always ensure the workpiece is firmly held or
clamped to prevent movement.
Any movement of the material may affect the
quality of the cutting or sanding finish.
Start your tool before working and turn it off
only after you stop working.
Do not start sanding without having the
sandpaper fitted.
Do not allow the sandpaper to wear away , it
will damage the sanding pad. The guarantee
does not cover sanding pad wear and tear.
Use coarse grit paper to sand rough surfaces,
medium grit for smooth surfaces and fine grit
for finishing surfaces. If necessary, first make a
test run on scrap material.
Excessive force will reduce the working
efficiency and cause motor overload.
10
Replacing the accessory regularly will
maintain optimum working efficiency.
MAINTAIN TOOLS WITH
CARE
Remove the plug from the socket before
carrying out any adjustment, servicing or
maintenance.
Your power tool requires no additional
lubrication or maintenance. There are no
user serviceable parts in your power tool.
Never use water or chemical cleaners to clean
your power tool. Wipe clean with a dry cloth.
Always store your power tool in a dry place.
Keep the motor ventilation slots clean. Keep
all working controls free of dust. Occasionally
you may see sparks through the ventilation
slots. This is normal and will not damage your
power tool.
If the supply cord is damaged, it must be
replaced by the manufacturer, its service agent
or similarly qualified persons in order to avoid
a hazard.
Oscillating Tool
PLUG REPLACEMENT
(UK & IRELAND ONLY)
If you need to replace the fitted plug then
followthe instructions below.

IMPORTANT

The wires in the mains lead are colored in
accordance with the following code:
blue – neutral
brown – live
As the colors of the wires in the mains lead
of thisappliance may not correspond with the
coloured markings identifying the terminals
in your plug,proceed as follows. The wire
which is coloured blue must be connected to
the terminal which is marked with N. The wire
which is coloured brown must be connected to
the terminal which is marked with L.
WARNING: Never connect live or
neutral wires to the earth terminal of the
plug. Only fit an approved 13A BS1363/A
plug and the correct rated fuse.
NOTE: If a moulded plug is fitted and has to
be removed take great care in disposing of the
plug and severed cable, it must be destroyed
to prevent engaging into a socket.
Connect
Blue to N
(neutral)
Outer sleeve
firmly clamped
13 Amp fuse approved
to BS1362
Brown L (live)
Cable grip
EN