INSTALLATION
mounting
AWG 560 V-GL / AWG 560 V-SR
3
1
2
1 Weather grille
2 Insert
3 Wall outlet
4 Hose clip with tensioning closure
AWG 315 L
2
1
1 Grille to keep out small animals
2 Insert
3 Wall outlet
4 Hose clip with tensioning closure
5 Insulating mat
AWG 560 L
3
2
1
1 Grille to keep out small animals
2 Insert
3 Wall outlet
4 Hose clip with tensioning closure
AWG 315-600
4
3
4
5
4
AWG 600 L
2
1
1 Grille to keep out small animals
2 Insert
3 Wall outlet
4 Hose clip with tensioning closure
Also part of the standard delivery:
- Four self-tapping screws (4.2 x 32) to connect the insert
and wall outlet
- Four screws (m5 x 10) for securing the weather grille to the
insert
- Installation aid:
Two sections for AWG 315 GL, AWG 315 SR, AWG 315 L
and AWG 600 L; three sections for AWG 560 H-GL,
AWG 560 H-SR, AWG 560 V-GL, AWG 560 V-SR and
AWG 560 L
- Thermal insulation tape
- Protective cover (fitted in the wall outlet)
- Two anti-drip caps (not for the AWG L)

3.2 Accessories

- Air deflector
4. Mounting
Damage to the appliance and environment
!
The weather grille is fitted with a drip edge to prevent
condensate running down the building envelope and
damaging the building. A prerequisite for this is that
the building envelope is vertical.
With the L versions, the drip edge is at the top and
serves to prevent water running down the wall from
reaching the wall outlet.
4.1
Installation location (only for AWG L)
Observe the minimum size of the cellar duct to enable an un-
restricted air flow (see "Specification / minimum dimensions
of the cellar duct").
Note
When sizing the cellar duct, please note that the insert
and weather grille have to be fitted from the outside.
3