Error Messages And Resetting The Boiler - Laars MASCOT HT 1.450 Notice D'installation Et D'entretien

Table des Matières

Publicité

4) To exit "INFO" mode, simply turn control knob 6 fully counter-
clockwise (see step 1 above) and repeat step 2.
Note: When you exit "INFO" mode, the "A..." message disappears and
central heating output temperature is displayed instead.
4.1)If there is no manual exit as described in point 4, after 5 minutes
approx the "view parameters" function will be interrupted auto -
matically. When automatic exit is tripped, the letter " d" will be
displayed, alternating with the boiler flow temperature value. The
display remains in this state until such time as the position of the
knob 6 (figure 21A) is changed, or until the boiler is disconnected
from the power supply.

4.10 ERROR MESSAGES AND RESETTING THE BOILER

If a fault occurs, the display reads out an error message identifying it.
Note: If the error message contains more than 2 digits (e.g. E133), the
display reads out the first two digits "E1" followed by the last two digits
"33", as shown in figure 22.1.
CODE DISPLAY FAULT DESCRIPTION /
Outdoor temperature probe sensor fault
10
Défaut capteur sonde extérieure
NTC flow sensor fault
20
Défaut capteur NTC de départ
Domestic hot water sensor fault
50
Défaut capteur NTC sanitaire
Safety thermostat tripped
110
Intervention du thermostat de sécurité
No signal from water pressure switch
119
Absence d?eau dans le circuit de l?installation
Flue thermostat sensor has cut out for overheat or
flue pressure switch has cut out for blocked vent
130
Intervention duthermostatdes fumées ou du pres -
sostatfumées (possible obstruction de la cheminée)
Gas supply fault
133
Manque de gaz
Boiler control card internal error
151
Erreur dans la carte de la chaudière
Fan speed threshold not reached
160
Seuil de vitesse du ventilateur non atteint
Fig. 22.1
4) Pour quitter la fonction "INFO", tourner le bouton 6 dans le sens
Remarque : lorsque la fonction "INFO" est désactivée, le message "A..."
disparaît de l'afficheur et ce dernier visualise la température de départ
du chauffage.
4.1)Si la sortie manuelle décrite au point 4 n'est pas effectuée, la fonc -
4.10 SIGNALISATIONS D?ANOMALIE ET DE R ÉARMEMENT DE
LA CHAUDI È RE
En cas d'anomalie, l'afficheur visualise un code d'avertissement .
Remarque : pour les codes d'anomalie comptant plus de 2 composants
(par ex. E133), l'afficheur visualise les deux premiers composants "E1"
suivis des deux derniers "33", comme le montre la figure 22.1.
DESCRIPTION DES SIGNAUX D?ERREUR
Call an authorised SERVICE centre.
Appeler le centre d'assistance technique agréé.
Turn selector (1) (figure 1) to "R" for at least 1 second. If this fault persists, call an authorised
SERVICE centre.
Mettre le sélecteur (1) (figure 1) sur "R" pendant au moins 1 seconde. En cas de déclenchement
répété de ce dispositif, a ppeler le centre d?assistance technique agréé.
Check that the pressure in the system is as specified. See the section on filling the system. If this
fault persists, call an authorised SERVICE centre.
Vérifier que la pression de l?installation soit correcte. Voir le chapitre Remplissage de la
chaudière. Si le probleme persiste , appeler le centre d?assistance technique agréé.
Turn selector (1) (figure 1) to "R" for at least 1 second. If this fault persists, call an authorised
SE RVICE centre.
Mettre le sélecteur (1) (figure 1) sur "R" pendant au moins 1 seconde. En cas de déclenchemen
répété de ce dispositif, a ppeler le centre d?assistance technique agréé.
Call an authorised SERVICE centre.
Appeler le centre d'assistance technique agréé.
Call an authorised SERVICE centre.
Appeler le centre d'assistance technique agréé.
29
inverse des aiguilles d'une montre (point 1) et répéter l'action décrite
au point 2.
tion "affichage paramètres" est interrompue automatiquement au
bout de 5 minutes. Lorsque la sortie automatique a lieu, l'afficheur
visualise la lettre " d" en alternance avec la valeur de la tempéra-
ture d'amenée. Ce message reste affiché jusqu?à ce que l'on déplace
la manette 6 (figure 21A) ou si l'on coupe l'alimentation électrique
de la chaudière.
t

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mascot ht 1.650

Table des Matières