L.B. White Sun Blast CR125AZPA220206 Manuel De L'utilisateur

Appareils de chauffage par rayonnement pour la construction
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

SCAN THIS QR CODE
with your smartphone or
visit http://goo.gl/nvneR
to view maintenance
videos for L.B.White heaters.*
*Requires an app like QR Droid for Android or
QR Reader for iPhone.
Owner's Manual and Instructions
MODELS
CR125AZPA220206 125,000 Btuh
CR125AZNA220207
Congratulations!
You have purchased the finest radiant construction heater available.
Your new L.B. White heater incorporates the benefits from the most experienced
manufacturer of heating products using state-of-the-art technology.
We, at L.B. White, thank you for your confidence in our products and
welcome any suggestions or comments you may have...call us, toll-free,
at 1-800-345-7200.
ATTENTION ALL USERS
This heater has been tested and evaluated by ETL in accordance with Standard ANSI
Z83.7 CSA 2.14 and is listed and approved as a direct fired construction heater for
use on combustible floors. This heater is intended for use as a portable, temporary
heater for buildings under construction, alteration, or repair. If you are considering
using this product for any application other than its intended use, then please
contact your fuel gas supplier, or the L.B. White Co., LLC
Sun Blast
Radiant Construction Heaters
View this manual online at www.lbwhite.com
OUTPUT
( 36.6 kW)
4009176
FUEL
Propane Vapor Withdrawal
Natural Gas
150-29533

Publicité

Chapitres

Table des Matières
loading

Sommaire des Matières pour L.B. White Sun Blast CR125AZPA220206

  • Page 1 *Requires an app like QR Droid for Android or QR Reader for iPhone. We, at L.B. White, thank you for your confidence in our products and welcome any suggestions or comments you may have...call us, toll-free, at 1-800-345-7200.
  • Page 2 Save this Owner’s Manual for future use and reference. ■ Owner’s Manuals and replacement labels are available at no charge. For assistance, contact L.B. White at 800-345-7200. WARNING ■ Proper gas supply pressure must be provided to the inlet of the heater.
  • Page 3: Table Des Matières

    Warranty Policy, Replacement Parts, and Service ......... .20 General Information When calling for technical service assistance, or for other Contact your local L.B. White distributor or the L.B. White Co., LLC for assistance, or if you have any questions specific information, always have model number, configuration number and serial number available.
  • Page 4: Heater Specifications

    Heater Specifications Model SPECIFICATIONS CR125 Propane Natural Fuel Input - BTUH (kW) 125,000 (36.6) Burner Manifold Pressure - in. W.C. (kPa) 10.0 (2.50) 5.55 (1.38) Fuel Consumption Per Hour 125 cu. ft. (9.3 m 3 ) 5.80 lbs.(2.63 kg) Dimensions - Inches (cm) 15 1/4 x 15 1/4 x 34 1/4 (38.7 x 38.7 x 87) L x W x H Minimum Safe Distances From...
  • Page 5: Safety Precautions

    Safety Precautions WARNING Asphyxiation Hazard ■ ■ Do not use this heater for heating human living Improper combustion can lead to carbon monoxide quarters, workshops, garages, or other such confined poisoning leading to serious injur y or death. spaces. Symptoms of carbon monoxide poisoning can include headaches, dizziness and difficulty in breathing.
  • Page 6 16. Minimum propane gas supply cylinder size to be used shall be 100 pounds (45 kg). When using a cylinder 2. All installations and applications of L.B. White heaters supply system, the system must be arranged to must meet all relevant local, state and national codes.
  • Page 7: Installation Instructions

    Force or follows: attempted repair may result in fire or explosion. WARNING 1. Read all safety precautions and follow L.B. White Fire and Explosion Hazard ■ recommendations when installing this heater. If Do not use open flame (matches, torches, candles, during the installation or relocating of heater, you etc.) in checking for gas leaks.
  • Page 8: Hose And Regulator Assembly

    -- Ensure all gas leaks have been identified and the heater in an propane liquid withdrawal system or repaired before proceeding. application. If you are in doubt, contact the L.B. White Co., LLC. 9. A qualified service agency must check for proper 13.
  • Page 9 HANDLE FIG. 4 WARNING HANDLE LOCK BRACKET Burn Hazard PUSH DOWN TO LOCK IN PLACE ■ Do not operate the heater with the handle installed. ■ Gripping the handle while the heater is operating or after the heater has been shut down can result in burns, causing injury.
  • Page 10: Lighting Instructions

    Lighting Instructions Slowly open the fuel supply valve at the gas supply. 3. To observe the pilot, move the pilot viewing cover to (This prevents lockup of the excess flow check valve the side. see Fig. 7. internal to the regulator’s POL fitting.) FIG.
  • Page 11: Cleaning Instructions

    Cleaning Instructions WARNING Fire, Burn, and Explosion Hazard ■ This heater contains mechanical components used in the gas management and safety systems. ■ Such components may become inoperative or fail due to dust, dirt, wear or aging. ■ Periodic cleaning and inspection as well as proper maintenance are essential to avoid serious injury or damage. ■...
  • Page 12: Service Instructions

    Service Instructions GENERAL 1. Close the fuel supply valve to the heater before WARNING ser vicing unless necessar y for your ser vice Burn Hazard procedure. ■ Heater surfaces are hot for a period of time after the heater has been shut down. 2 Disconnect the gas hose if needed for the service ■...
  • Page 13: Pilot Orifice

    PILOT ORIFICE A plugged orifice creates a poor pilot flame, leading to 2. Loosen the pilot tube’s compression fitting at the pilot outages. The pilot flame should impinge on the pilot orifice. See Fig.11. thermocouple tip as shown in Fig. 10. If the pilot flame appears weak, the pilot orifice may 3.
  • Page 14: Igniter And Electrode

    IGNITER and ELECTRODE Servicing of the igniter and electrode is needed when a spark B. Electrode is not observed at the electrode when pushing the igniter button. This may happen with hard use over a period of time, 1. Ensure the wire between the electrode and the igniter is dust and dirt accumulation, or improper gap securely connected.
  • Page 15: Gas Pressure Checks

    GAS PRESSURE CHECKS ■ This procedure is to be done once a year prior to the C. READING PRESSURES heating season, anytime the heater is moved from one job location to the next, or after servicing the heater. 1. Light the heater. With the heater operating, the pressure gauge should read the pressure specified on the dataplate or in the specification section of this owner’s manual.
  • Page 16: Troubleshooting

    Troubleshooting Information PROBLEMS CAUSES REMEDIES 1. Pilot will not light. * Fuel supply valves closed. * Open fuel supply valves. * Pilot button not fully depressed. * Depress pilot button completely. * Pilot orifice is plugged. * Clean or replace pilot orifice. * Inlet screen at pilot orifice is * Clean or replace screen.
  • Page 17: Heater Component Function

    Heater Component Function BURNER REGULATOR Component at which combustion of fuel gases takes place. The heart of any gas supply installation. Used to deliver a working pressure to the appliance under varying conditions BURNER ORIFICE in tank pressure. Metering device used to feed gas to burner at a specific rate, with the appropriate pressure.
  • Page 18: Parts Identification

    Parts Identification Parts Schematic...
  • Page 19: Parts List

    Parts List Item Description Part Number Regulator w/ hose,LP gas 573271 Regulator, Natural gas (not shown) 573272 Adapter 573323 Nipple 573278 Clamp 573279 Bracket 573321 Knob, gas control valve 573265 Pilot safety control valve, with knob 573264 Burner manifold 573280 Burner orifice, LP gas 573281 Natural gas...
  • Page 20: Warranty Policy

    Warranty Policy HEATER L.B. White Co., LLC warrants that the component parts of its Registering your product online with L.B.White will heater are free from defects in material and workmanship, automatically qualify a unit and its component parts for when properly installed, operated, and maintained in warranty consideration.
  • Page 21: A Tous Les Utilisateurs-Veuillez Prendre Note

    QR Reader pour iPhone. appareils de chauffage. L.B. White, tient à vous remercier de la confiance que vous lui témoignez et vous invite à lui communiquer tout commentaire ou suggestion, sans-frais, au 1-800-345-7200 A TOUS LES UTILISATEURS-VEUILLEZ PRENDRE NOTE : Cet appareil a été...
  • Page 23: Mise En Garde Générale

    ■ Les manuels de l'utilisateur et les étiquettes de remplacement sont offerts gratuitement. Veuillez contacter votre détaillant ou L.B. White Co. LLC au 1-800-345-7200 ATTENTION ■ L'arrivée de gaz de l'appareil doit être alimenté par une pression de gaz adéquate.
  • Page 24: Informations Générale

    Veuillez communiquer avec votre détaillant local de produits et de maintenir votre appareil en bon étât de L.B.White ou avec L.B. White directement pour toute fonctionnement. S'assurer que votre installateur qualifié interrogation ou assistance au sujet de cet appareil et son passe en revue les différentes sections de ce manuel en...
  • Page 25: Spècifications

    Spècifications Model SPECIFICATIONS CR125 Combustible Propane Naturel Puissance (kW) 36,6 Pression au manifold du brûleur (kPa) 2,50 1,38 9,3 m 3 2,63 Consommation de combustible à l'heure Dimensions - (cm) 38,7 x 38,7 x 87 L x W x H DESSUS 1,52 Distance minimales de dégagement...
  • Page 26: Consignes De Sécurité

    Consignes de sécurité ATTENTION Risques d'asphyxie ■ ■ Ne pas utiliser cet appareil pour le chauffage d'un Une combustion inadéquate peut entrainer des logement habité, garages, ateliers, ou autres espaces blessures sérieuses ou la mor t suite à un confinés.. empoisonnement au monoxyde de carbone.
  • Page 27 2. L'utilisation et l'installation des appareils de chauffage fuites dans la section Installation du présent manuel. de L.B. White doit en tout temps répondre aux normes et 13. Cet appareil devrait faire l'objet d'une inspection avant règlementations en vigueur aux niveaux municipal, chaque utilisation par une personne qualifiée ainsi qu'au...
  • Page 28: Directives D'installation

    1. Lire toutes les consignes de sécurité et suivre les s'installé il n'est pas directement exposé pour arroser recommandations de L.B. White lors de l'installation le spray, la pluie, ou dégoutter l'eau. de votre appareil de chauffage. Si, au cours de l'installation ou en déplaçant l'appareil, vous...
  • Page 29: Toute Pièce Défectueuse Découverte En Cours

    à un -- Advenant la présence d’une fuite, vérifier la soutirage de propane liquide. En cas d’interrogations, consulter L.B. White Co. LLC. propreté et l’intégrité des pièces en cause ainsi que l’étât de la pâte isolante aux branchements 13.
  • Page 30: Assemblage Du Boyau D'alimentation Et Du Régulateur

    ASSEMBLAGE DU BOYAU D'ALIMENTATION ET DU REGULATEUR ■ Raccorder l’extrémité opposée du boyau à la valve de FIG. 1 contrôle au niveau de l’appareil de chauffage à l’aide d’un écrou. Bien serrer le raccord. Consulter la figure ADAPTATEUR DE BOYAU DU BOYAU ET LE RÉGULATEUR SONT PRE-ASSEMBLE BRANCHEMENT DU RÉGULATEUR À...
  • Page 31: Poignée

    POIGNÉE ■ Installer la poignée tel qu’illustré dans la figures 3 et FIG. 4 POUSSER LE SUPPORT VERS LE BAS POUR LE VERROUILLER MISE EN GARDE Risque de brûlure ■ Ne pas faire fonctionner l’appareil de chauffage lorsque la poignée est installée. ■...
  • Page 32: Directives Pour L'allumage

    Directives pour l'allumage 1. Ouvrir lentement la valve d’alimentation en gaz au 3. Pour observer la veilleuse, ouvrir latéralement le niveau de l’alimentation en gaz. (Cela permet de couvercle de visionnement de la veilleuse. Consulter la prévenir le blocage de la valve de contrôle du débit figure 8.
  • Page 33: Directives De Nettoyage

    Les étiquettes endommagées sur le radiateur. doivent être remplacées immédiatement; veuillez, pour ce faire, prendre contact avec la L.B. White Co., LLC. 3. Il se pourrait que le régulateur s'use et ne fonctionne pas correctement. Demandez à votre fournisseur de 6.
  • Page 34: Directives Pour Le Service

    Directives pour le service GÉNÉRALITÉS 1. Fermer la valve d'alimentation en gaz de l’appareil de AVERTISSEMENT chauffage avant de procéder à l’entretien ou à la Risque de brûlure réparation sauf s’il est nécessaire qu’elle soit ouverte ■ Les surfaces de l’appareil de chauffage restent pour effectuer la procédure.
  • Page 35: Barillet D'orifice Della Veilleuse

    BARILLET D'ORIFICE DE LA VEILLEUSE Un orifice obstrué cause une veilleuse inadéquate, ce qu 2. Desserrer le raccord de compression du tube de la i peut entraîner son extinction. La veilleuse devait toucher veilleuse au niveau de l’orifice de la veilleuse. l’extrémité...
  • Page 36: Allumeur Et Électrode

    ALLUMEUR et ÉLECTRODE Il est nécessaire de procéder à la réparation de l’allumeur et B. Électrode de l’électrode lorsque aucune étincelle n’est visible au niveau de l’électrode après avoir enfoncé le bouton-poussoir de 1. S’assurer que le fil reliant l’électrode à l’allumeur est l’allumeur.
  • Page 37: Verification De La Pression De Gaz

    VÉRIFICATION DE LA PRESSION DE GAZ ■ Cette vérification doit être effectuée une fois l'an avant le 2. Installer un coude de 1/8 po et un manomètre à cet début de la saison froide, après chaque déplacement de endroit. Consulter la figure 17. l'appareil ainsi qu'après un entretien.
  • Page 38: Dépannage

    Dépannage PROBLEMES CAUSES SOLUTIONS 1. La veilleuse ne s’allume pas. * Le réservoir de propane est vide. * Remplir le réservoir. * Les valves d’alimentation en gaz sont fermées. * Ouvrir les valves d’alimentation en gaz. * La valve de contrôle du débit * Fermer la valve du réservoir de excédentaire du P.O.L.
  • Page 39: Fonction Des Différentes Composantes De L'appareil

    Fonction des différentes composantes de l'appareil BRÛLEUR RÉGULATEUR Composantes où a lieu la combustion du gaz alimentant La pièce maîtresse de tout système alimenté au gaz. Utilisé l'appareil. pour fournir une pression de gaz appropriée à l'appareil sous différentes conditions variantes à la source (réservoir). ORIFICE DU BRÛLEUR Instrument de régulation en laiton qui alimente le brûleur en VALVE DE CONTRÔLE...
  • Page 40: Identification Des Pièces Composantes

    Identification des pièces composantes Schéma des pièces composantes...
  • Page 41: Liste Des Pièces Composantes

    Liste des pièces composantes Item Description Numéro de la pièce Régulateur avec raccord et Boyau, Propane 573271 Régulateur, Gaz naturel (non illustré) 573272 Adaptateur 573323 Mamelon 573278 Bride de serrage 573279 Support 573321 Bouton, valve de contrôle du gaz 573265 Valve de contrôle de la veilleuse, avec bouton 573264 Manifold du brûleur...
  • Page 42: Garantie

    Si entretenus selon les directives d'installation et d'entretien, un produit n'a pas été enregistré chez L.B. White, une copie ainsi que des consignes de sécurité émises et des du contrat de vente sera requise afin qu'un produit soit étiquettes et fiches fournies avec chaque appareil.

Ce manuel est également adapté pour:

Sun blast cr125azna220207

Table des Matières