Accuracy (cont'd)
DM-210A and DM-510A Only
Capacitance
Range
60.00 nF
600.0 nF
6.000 µF
60.00 µF
600.0 µF
3000 µF
Accuracies are for film capacitors (capacitors
with negligible dielectric absorption);
measurements of larger capacitors can take
up to 30 seconds
DM-510A Only
AC Voltage AutoCheck™ Mode
Range (50/60 Hz)
6.000 V
60.00 V
600.0 V
1000 V
Input Impedance: Initial 2.5 kΩ // 120 pF
typical at voltages up to 50 V; increases with
voltage to approximately 375 kΩ at 1000 V
AutoCheck™ Trigger Level: > 1.0 V
(50/60 Hz) typical
Resistance AutoCheck™ Mode
Range
600.0 Ω
6.000 kΩ
60.00 kΩ
600.0 kΩ
6.000 MΩ
60.00 MΩ
Open Circuit Voltage: 0.45 VDC typical
AutoCheck™ Trigger Level: < 10.00 MΩ
typical
20
Accuracy
± (2.0% + 0.05 nF)
± (2.0% + 0.5 nF)
± (1.5% + 0.005 µF)
± (1.5% + 0.05 µF)
± (1.5% + 0.5 µF)
± (2.0% + 5 µF)
Accuracy
± (1.4% + 0.005 V)
± (1.4% + 0.05 V)
± (1.4% + 0.5 V)
± (1.4% + 5 V)
Accuracy
± (1.2% + 1.0 Ω)
± (1.2% + 0.010 kΩ)
± (1.2% + 0.10 kΩ)
± (1.2% + 1.0 kΩ)
± (1.2% + 0.010 MΩ)
± (1.2% + 0.10 MΩ)
Temperature
Range
-50 °C to 1000 °C
-58 °F to 1832 °F
The accuracy information is for the meter
only; refer to the information sheet provided
with the temperature probe (purchased
separately) for its accuracy
DC Voltage AutoCheck™ Mode
Range
6.000 V
60.00 V
600.0 V
1000 V
Input Impedance: Initial 2.5 kΩ // 120 pF
typical at voltages up to 50 V; increases with
voltage to approximately 375 kΩ at 1000 V
AutoCheck™ Trigger Level: > +1.0 VDC and
< -1.0 VDC typical
Record Mode (Voltage and Current) for
recording signal maximums and minimums
≥ 100 ms in duration
Accuracy: Specified accuracy + 100 digits
Crest Capture (Voltage and Current) for
Crests ≥ 5 ms in duration
Accuracy: Specified accuracy ± 150 digits
Accuracy
± (0.3% + 3 °C)
± (0.3% + 6 °F)
Accuracy
± (1.3% + 0.003 V)
± (1.3% + 0.03 V)
± (1.3% + 0.3 V)
± (1.3% + 3 V)