AUDIO VIDEO IP WITH 1-6 PB DOOR ENTRY STATION
USE
Station IP address
Each station must have its own IP address on the network. This address will be either given by the network server
(DHCP addressing) or configured manually. This addressing can be configured from a PC via the station's Web
server.
Note that the station is delivered by default with DHCP. If no DHCP server is present, the station will then use
a fixed IP address of the IP4All domain: 169.254.xx.xx
The discovery of the station's IP address is possible from:
The CastelIPSearch software
The CastelServeur software
Any ONVIF discovery software
If the discovery of the workstation's IP address is not possible:
In factory settings mode, when pressing the 1
address
The station also announces its IP address when the 'Soft Reset' push button is pressed briefly
When the 'Soft Reset' push button is pressed for more than 3 seconds, the station bridges its IP
interfaces with a fixed IP at 192.168.49.251.
Station reset
When the 'Soft Reset' push button is pressed for more than 20 seconds, the station restarts and resets its parameters
to the factory settings.
When pressing the 'Hard Reset' button, the station restarts instantly.
Access to the station Web Server
To log into the station Web server, simply use a web browser such as Chrome, Edge or Firefox. Open your Web
browser from any PC on the same network and type: 'https://' followed by the IP address of the station
([https://station_ip_address]). You will then be directly connected to the station's Web page. Enter your login (by
default: castel) and your password (by default: castel) to access the functions of the Web server.
Note: an online help accessible from all the menus can be used to find out about the different functions of the Web
server.
MAINTENANCE
Your CASTEL product must only be cleaned using a mild cleaning product (water or soapy water) that is non-
abrasive, non-foaming and above all free from any type of solvent or alcohol.
For regular maintenance, only use water, without detergent.
Jet cleaning must be prohibited, as well as use of abrasive sponges and cloths with aggressive surfaces.
Technical data sheet no. 604-0090J
st
programmable button, the station announces its IP
www.castel.fr