Castel XELLIP Serie Manuel D'instructions page 14

Masquer les pouces Voir aussi pour XELLIP Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

AUDIO VIDEO IP WITH 1-6 PB DOOR ENTRY STATION
OPTIONS
Reference 590.9220: Belt
Reference 590.9400: Cap
Reference 590.9600: Claw kit (plasterboard mounting)
CONNECTION
Power supply connection (24VDC)
The required power supply is 20 at 30VDC.
Note: The door entry station can be powered by PoE+ or PoE
Ethernet (with some restrictions)
Your device is delivered from the factory in PoE / PoE+
configuration, however in some cases it may be necessary to
block it in a PoE configuration alone (distribution of the power of
the Switch on several gatekeepers / poor power management of
the Switch /. ..).
In this case with the device not powered and with a small non-
conductive clamp, remove the strap indicated in red on the
photo below
IP network connection (ETH0 / ETH1)
The connection is made via a 10/100/1000 Mbits Ethernet RJ45
class 5e or 6 link.
2 Available Ethernet port (1 PoE or PoE+ and 1 non PoE
compatible)
Connection of 0dB output (0dB +/-)
version 1.5.0
A 0dB differential output allows the connection of an external
amplifier.
+: Hot spot
-: Cold point
0V: GND
Magnetic Loop Loop Output Connection (Loop)
A Loop output allows the connection of the magnetic induction
loop.
Connection to the VDIP RS485 bus
The device is connected to the VDIP RS485 devices (VD4S réf 110.1000, VD8EI réf 110.1100, VDLECT réf
110.1200) via a RS485 bus line (bus wiring: several devices can be installed on one bus line).
The bus connection between the peripherals and the module is made by points RS1 and RS2 (via a twisted pair) and
the ground. Establish the point-to-point connection by following the order of the signals.
The maximum length of the bus is 1 km. A 120Ω resistor needs to be fitted (provided with the RS485 device) between
points RS1 and RS2 at each end of the bus.
Input connection (IN1 / IN2 / 0V)
Two digital inputs allow the connection of a dry contact (do not apply voltage). To be activated, the input must be
grounded.
The contact can be deported up to 1Km.
Technical data sheet no. 604-0090J
Applicable from software
Configurable with CASTELSuite
www.castel.fr
FR
EN
Page 14 / 24

Hide quick links:

Publicité

Table des Matières
loading

Table des Matières